beautypg.com

SkyTrak 6036 Service Manual User Manual

Page 207

background image

Section 10.

Electrical System

Model 6036 S/N 9B0499 and Before

10-13

4.

Select the voltmeter range that will measure
12 V and release the starter button.

5.

If the voltage indication was:

a. 0.5 Vdc or less, complete Test 5.
b. More than 0.5 V, complete Test 3 and

Test 4.

Fig. 10.12 Measuring Voltage Loss

in Starter Solenoid

e.

Test 4—Voltage Loss in Starter Solenoid

1.

Connect the positive lead of the voltmeter to
the battery terminal on the starter solenoid,
Fig. 10.12.

2.

Connect the negative lead of the voltmeter to
the motor terminal on the starter solenoid.

3.

Select voltage range that will measure 12 Vdc.

4.

Push in and hold the starter button and select
the lowest voltage range for the voltmeter;
read the voltmeter.

5.

Select the voltage range that will measure 12
Vdc and release the starter button.

6.

If the voltage indication was more than 0.1 V,
replace the starter solenoid.

Fig. 10.13 Measuring Voltage Loss in Negative

Battery Cable

f.

Test 5—Voltage Loss
in Negative Battery Cable

1.

Connect the negative lead of the voltmeter to
the negative battery cable at the batteries, Fig.
10.13.

2.

Connect the positive lead of the voltmeter to
the negative battery cable at the starter
mounting nut.

3.

Select lowest voltage range for the voltmeter.

4.

Push in and hold the starter button and read
the voltmeter.

5.

If the voltmeter indication was:

(a) More than 0.4 V, replace the negative

battery cable.

(b) 0.4 V or less, the negative battery cable is

good.

Fig. 10.11 Measuring Voltage Loss in Positive

Battery Cable

d. Test 3—Voltage Loss

in Positive Battery Cable

1.

Positive lead of voltmeter stays connected to
the positive battery cable, Fig. 10.11.

2.

Select lowest voltage range for the voltmeter.

3.

Connect the negative lead of the voltmeter to
the battery terminal of the starter solenoid.

4.

Push in and hold the starter button, and read
the voltmeter.

5.

If the voltage indication was:

a. More than 0.4 V, replace the battery cable.
b. 0.4 V or less, complete Test 4.

STARTER

BATTERY

TERMINAL

STARTER

MOTOR

TERMINAL

BATTERY

TERMINAL

STARTER

GROUND

STARTER

MA0941

MA0951

MA0961