Control rack terminal identification, Dynaflow, User manual - maintenance – Ransburg DynaFlow User Manual User Manual
Page 86: Mother board signal identification, J3, 4, 5, 6 channel modules
LN-9400-00.9
82
DynaFlow
TM
User Manual - Maintenance
CONTROL RACK
TERMINAL
IDENTIFICATION
MOTHER BOARD SIGNAL IDENTIFICATION
1B
2B
3B
4B
5B
6B
7B
8B
9B
10B
11B
12B
13B
14B
15B
16B
17B
18B
19B
20B
21B
22B
23B
24B
25B
26B
27B
28B
29B
30B
31B
32B
Flow Meter Input #1A
Flow Meter #1A GND
Flow Meter Input #1B
Flow Meter #1B GND
Flow Meter Input #2A
Flow Meter #2A GND
Flow Meter Input #2B
Flow Meter #2B GND
CAN BUS+
CAN BUS-
CAN BUS GND
+24 VDC
PWR GND
J3, 4, 5, 6
CHANNEL MODULES
Pin # Description
1A
2A
3A
4A
5A
6A
7A
8A
9A
10A
11A
12A
13A
14A
15A
16A
17A
18A
19A
20A
21A
22A
23A
24A
25A
26A
27A
28A
29A
30A
31A
32A
Analog Set Point Input #1
Spare Analog Input #1
Analog Input GND
Analog Transducer Control #1
Analog Flow Rate Output #1
Analog Output GND
Trigger Input #1
Run Input #1
Transparent/PID Input #1
Total Hold Input #1
Digital Input GND
Gun Mask Input #1
Halt Input #1
Total Reset Input #1
Clean Input #1
Digital Input GND
Load Input #1
Analog Hold Input #1
External Fault Input #1
Spare Input #1
Digital Input GND
Ready Output #1
Active Output #1
Fault Output #1
Pot Life Timer Output #1
Clean/Load/Calibrate Output #1
MVR Enable Output #1
Digital Output GND
Console Rx232
Console GND
+24 VDC
PWR GND
J3, 4, 5, 6
CHANNEL MODULES
Pin # Description