Parameters
The controlling parameters for each GUN, and for
the CHANNELs assigned to that GUN, are called
JOBs (also commonly referred to as PSETs, Color
Tables or Recipes). The JOB values define flow
characteristics such as TARGET FLOW RATE,
MIX RATIO, FLOW TOLERANCE, etc. JOBs
include all of the parameters that may be depen-
dent on the material used. This offers the ability
to optimize system control as needed per material
and then recall the settings each time that mate-
rial is requested. There are up to 100 JOB #s for
each GUN. By saving frequently used JOB #s to
memory you can later recall them by loading the
number representing that JOB #. The parameters
are viewed and edited through the local Operator
Interface or through a remote host computer.
A set of initial parameter values is included in the
controller. The initial (default) values determine the
operating conditions of the controller when started
for the first time. Some of these will need to be
edited during initial setup based on the installation.
Slave Channel =
Material = 3
rd
Component
Flow Controller = MVR, with appropriate
size needle
Flow Meter = Piston or Gear-Type,
depending on
min/max flow rates
(see Notes 4 and 5)
Operating Mode = Manual or Auto
(see Notes 1, 2, and 3)
NOTES:
1. If the output of Gun 2 supplies one or more
hand guns, then Gun 2 should be operated in
Manual mode using a CCV for the Master Chan-
nel flow controller.
2. If the output of Gun 2 supplies a single appl-
icator, then an MVR should be used for the Mas-
ter Channel flow controller and Gun 2 should be
operated in Auto mode.
3. If the output of Gun 2 supplies multiple appl-
icators other then hand guns, then Gun 2 should
be operated in Manual mode using a CCV for
the Master Channel flow controller. Additional
Guns should be configured for each applicator
as shown
below to provide automatic flow
control for each applicator.
Gun 3 through 6 =
Master Channel =
Material = Output of Gun 2 (Resin + 2
nd
+ 3
rd
Components)
Flow Controller = DR1
Flow Meter = Gear-Type
Operating Mode = Auto
4. Minimum flow rate for the DynaFlow is deter-
mined for each channel based on the number
of pulses/liter for the flow meter for the channel.
(Refer to "Addendum C" for flow limitations.)