User manual - introduction – Ransburg DynaFlow User Manual User Manual
Page 17
LN-9400-00.9
Channel Module Hardware Specifi-
cations (Cont.)
DynaFlow
TM
User Manual - Introduction
13
FLOW RATE JOB parameters)
4 Frequency Inputs:
From flow meters (reverse
flow capable)
Source Signal #1 & #2:
Frequency used to determine
flow rate (pulses per volume or
weight).
Maximum Frequency = 435 Hz
Minimum Frequency = 1 Hz
(Refer to Addendum C for flow limitations.)
Phase Signal #1 & #2: State used to determine
direction of flow rate, forward or
reverse.
PID Control:
Closed loop control based on
the Kp, Ki, Kd and deadband
JOB parameters. 30ms PID up
date time (default), each chan-
nel.
Communications
CAN:
Controller Area Network (CAN) High-
speed serial communications to In-
terface Module.
RS-232C Port:
Spare auxiliary communication port.
Power Requirements:
24 VDC at 100 ma
typical – each Channel Module
Operating
Temperature:
0
o
to 55
o
C
Interface Enclosure (A12182)
Dimensions:
610mm H X 610mm W X 410mm D
Weight:
22.7 Kg (50 lbs)
Temperature:
5°C - 40° C
Humidity:
80% to 31° C decreasing to 50% at
40° C non-condensing
Control Enclosure (A12233)
Dimensions:
610mm H X 610mm W X 410mm D
Weight:
45.5 Kg (100 lbs)
AC Power:
115/230 VAC, 3A
50/60
HZ
1
Phase
Temperature:
5°C - 40° C
Humidity:
80% to 31° C decreasing to 50% at
40° C non-condensing