Dynaflow specifications, Dynaflow, User manual - introduction – Ransburg DynaFlow User Manual User Manual
Page 15
LN-9400-00.9
DYNAFLOW
SPECIFICATIONS
Transducers:
The air supplied to the trans-
ducers must be clean and dry
and meet the following general
specifications:
Filtration:
20 Micron
Supply Pressure:
90 PSIG min. to 150 PSIG
max.
Volume:
0.04 to 0.13 Cv
Operating Temperature:
32
o
to 150
o
F (0
o
to 65.5
o
C)
Dimensions:
83mm H X 250mm W X
184mm D standard half rack
Power Requirements:
24 VDC at 1 Amp typical, all 8
CHANNELs installed
The following must be followed if the flow control
rack and/or Operator Interface is to be integrated
into a larger system control panel:
- The 24 VDC Power Supply must be located in the
same control panel as the fluid flow control.
-
DO NOT use a central power supply located else
where. The power supplies may be sized for and
used for other controls within the same cabinet
WITH THE EXCEPTION OF HIGH VOLT-
AGE POWER SUPPLY CONTROLLERS.
High voltage power supply controllers MUST have
a dedicated power supply.
Pneumatic Requirements
Control Rack (Up to 8 Channels Per
1/2 of 19" Rack)
Interface Module Hardware
Interface Module Hardware (Cont.)
Digital Inputs:
24 VDC at 2.3 ma typical per input
(optically isolated, source by de-
fault, sink selectable)
- JOB Select Strobe
- JOB Select 1 (lower significant
BCD digit)
- JOB Select 2
- JOB Select 4
- JOB Select 8
- JOB Select 10 (middle significant
BCD digit)
- JOB Select 20
- JOB Select 40
- JOB Select 80
- JOB Select 100 (upper significant
BCD digit)
- System Ready/Halt
- Global Gun Enable
Digital Outputs:
24 VDC sourced at 300 ma maxi-
mum per output (Solid state relay
contacts)
System Pulse:
Used as watchdog timer by an
external supervisory PLC or com-
puter.
System Fault:
Used to activate an alarm and to
supply a signal remotely that a
System, GUN, or other fault has
occurred.
Communications
RS-232C Port:
Communication with local
Opperator Interface unit.
Allen-Bradley
RIO Port:
For direct high-speed communi-
cation with Allen-Bradley PLC's.
CAN:
Control Area Network (CAN) high
speed communication with all
channel Modules and with other
racks.
Power Requirement:
24 VDC at 100 ma typical
Operating Temperature:
0
o
to 55
o
C
DynaFlow
TM
User Manual - Introduction
11
General:
This Module is responsible for
local display/keyboard control and
communication to the Host control-
ler. Responsible also for non-vola-
tile storage of all JOB data tables
and system configuration param-
eters.
Dimensions:
3U (130.5 mm) H x 7H
(35.2 m) W standard 19" rack module