User Manual - Maintenance

for a total of 32 seconds without faulting. As soon

as the controller senses flow from the master

CHANNEL, the timer is reset and will start once

again the next time a trigger signal is received

with no master CHANNEL flow.

Corrective Action:

In most cases, this fault is generated by the master

CHANNEL flow meter gears not turning (usually

stuck). Try flushing the system and watch the flow

rate or flow volume on the operator interface. If

there still is no flow, disassemble and clean the

flow meter. If this still does not correct the prob-

lem, see the section in this manual on FLOW

TOO LOW FAULTS. If this fault occurs while the

operator was not trying to spray, then the air flow

switch may be defective. This can be verified by

the GUN status on the operator interface.

SYSTEM PREVENTIVE

MAINTENANCE

INSTRUCTIONS

Control Panels

There is no maintenance schedule for control

panels other than good housekeeping practices.

These include.

• Keeping the door closed at all times. This

will maintain the dust-tight environment

required by the electronic printed circuit

boards.

• Plug all unused access holes into the cabinet

in order to keep contamination out.

• Use the following guidelines for cleaning

the Operator Interface:

Use cleaning solution specifically formu-

lated for computer monitors, a mild win-

dow cleaner, or isopropyl alcohol.

DO

NOT use solvents. Most importantly,

use a clean, soft paper towel or tissue

and use very light force.

Fluid Control Components

It is recommended to record system settings such

as fluid supply and air supply pressures, etc.

Reference the appropriate service literature for

maintenance instructions.