Dynaflow, User manual - maintenance – Ransburg DynaFlow User Manual User Manual
Page 83

LN-9400-00.9
79
DynaFlow
TM
User Manual - Maintenance
The new 12-bit Channel Card for the DynaFlow (P/N: A10946) has a different jumper configuration
than the now obsoleted 8-bit module (P/N: 77206-11). Please refer to the table below when setting
the jumpers on the new channel cards.
Jumper Description
JMP1
JMP2
JMP3
JMP4
Flow Rate Setpoint, Ch. A
Spare Input, Ch. A
Flow Rate Setpoint, Ch. B
Spare Input, Ch. B
Analog Inputs:
FactorySetting
X
X
X
X
Type
0-10 VDC
4-20 mA
0-10 VDC
4-20 mA
0-10 VDC
4-20 mA
0-10 VDC
4-20 mA
Pin 1-2
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Pin 2-3
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Jumper Description
JMP5
JMP6
JMP7
JMP8
Control Pressure, Ch. A
Actual Flow, Ch. A
Control Pressure, Ch. B
Actual Flow, Ch. B
Analog Outputs:
FactorySetting
X
X
X
X
Type
0-10 VDC
4-20 mA
0-10 VDC
4-20 mA
0-10 VDC
4-20 mA
0-10 VDC
4-20 mA
Pin 1-2
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Pin 2-3
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Jumper Description
JMP9
JMP10
JMP11
JMP12
JMP13
JMP14
Trigger, Ch. A
Run Mode, Ch. A
Transparent Mode, Ch. A
Total Hold, Ch. A
Gun Mask, Ch. A
Halt, Ch. A
Total Reset, Ch. A
Clean Mode, Ch. A
Load Mode, Ch. A
Analog Hold, Ch. A
External Fault, Ch. A
Spare Input, Ch. A
Trigger, Ch. B
Run Mode, Ch. B
Transparent Mode, Ch. B
Total Hold, Ch. B
Gun Mask, Ch. B
Halt, Ch. B
Total Reset, Ch. B
Clean Mode, Ch. B
Load Mode, Ch. B
Analog Hold, Ch. B
External Fault, Ch. B
Spare Input, Ch. B
Discrete (Digital) Inputs:
FactorySetting
X
X
X
X
X
X
Type
Source
Sink
Source
Sink
Source
Sink
Source
Sink
Source
Sink
Source
Sink
Pin 1-2
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Pin 2-3
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open