B-2 Processor Status File

S:2Switch setting information

S:2/00
through
S:2/05

Channel 1A DH+ station number

S:2/06

Channel 1A DH+ baud rate

057.6 kbps

1230.4 kbps

S:2/07
S:2/08

Not defined

S:2/09

Last state

0outputs are turned off

1outputs retain last state

S:2/11
S:2/12

I/O chassis addressing

bit 12bit 11
00illegal
101/2-slot
011-slot
112-slot

S:2/13
S:2/14

Memory module transfer

bit 14bit 13
00memory module transfers to controller memory
if controller memory is not valid
01memory module does not transfer to
controller memory
11memory module transfers to controller memory
at powerup

S:2/15

Controllercontroller memory protection

0enabled

1disable

This Word

Stores