Preparing Fault Routines
Using This Chapter
Understanding the Fault
Routine Concept
Fault routines execute when a PLC-5 controller encounters a major fault
during program execution.
Use a fault routine to specify how you want the controller to respond to a
major fault. If your controller experiences a fault during program execution,
you can tell the controller to interrupt the current program, run your fault
routine, and then continue processing the original program.
A fault routine processes the major fault bit found in S:11 and determines the
course of program execution based on the fault bit present. Fault routines
provide a means to either:
•
systematically shut down a process or control operation
•
log and clear the fault and continue normal operation
For a detailed list of the words in the controller status file, see
Appendix B.
Responses to a Major Fault
When the controller detects a major fault, the controller immediately
interrupts the current program. If a fault routine exists (i.e., program file is
specified in S:29 as a fault routine), the controller runs that fault routine
program for recoverable faults. Depending on the type of fault, the controller
then: