Specifying machine functions (software switch settings)
2
2.5.25
Specifying settings concerning the communication results of IP relay operations
(mode 382)
Specify the length of time until the communication results for an IP relay operation times out and the specified
operation is performed.
Factory settings
Specifying the settings
During the production of this unit, the settings in the shaded cells were selected.
!
Detail
If the specified timeout time is short (for example, 5 or 10 minutes), the status of a document queued
to be sent from a relay machine or the G3 transmission time between the relay machine and recipient
may cause a timeout (failed transmission).
Bits
7654 3210
Settings
0100 0000 (HEX: 40)
Bits
Description
Settings
Details
7
Specify the operation that is performed when the return of
communication results for an IP relay operation times out.
0
Transmission error
1
Normal transmission
6-3
Specify the length of time until communication results for an
IP relay operation times out.
0000
0 minute
0001
5 minutes
0010
10 minutes
0011
15 minutes
0100
20 minutes
0101
30 minutes
0110
40 minutes
0111
50 minutes
1000
1 hour
1001
2 hours
1010
3 hours
1011
4 hours
1100
5 hours
1101
6 hours
1110
7 hours
1111
8 hours
2-0
−
000
*Do not change the settings