beautypg.com

Factory settings, Specifying the settings, P. 2-37 – Konica Minolta bizhub C200 User Manual

Page 86

background image

C200

2-37

Specifying machine functions (software switch settings)

2

2.5.25

Specifying settings concerning the communication results of IP relay operations
(mode 382)

Specify the length of time until the communication results for an IP relay operation times out and the specified
operation is performed.

Factory settings

Specifying the settings

During the production of this unit, the settings in the shaded cells were selected.

!

Detail

If the specified timeout time is short (for example, 5 or 10 minutes), the status of a document queued
to be sent from a relay machine or the G3 transmission time between the relay machine and recipient
may cause a timeout (failed transmission).

Bits

7654 3210

Settings

0100 0000 (HEX: 40)

Bits

Description

Settings

Details

7

Specify the operation that is performed when the return of
communication results for an IP relay operation times out.

0

Transmission error

1

Normal transmission

6-3

Specify the length of time until communication results for an
IP relay operation times out.

0000

0 minute

0001

5 minutes

0010

10 minutes

0011

15 minutes

0100

20 minutes

0101

30 minutes

0110

40 minutes

0111

50 minutes

1000

1 hour

1001

2 hours

1010

3 hours

1011

4 hours

1100

5 hours

1101

6 hours

1110

7 hours

1111

8 hours

2-0

000

*Do not change the settings
for these bits.