Factory settings, Specifying the settings, Specfying the settings – Konica Minolta bizhub C200 User Manual
Page 73: P. 2-24
C200
2-24
Specifying machine functions (software switch settings)
2
2.5.5
Specifying whether or not a received date report is added and its format (mode 016)
Specify whether or not a received date report is added and how it is formatted when a network fax or fax is
received.
Factory settings
Specifying the settings
During the production of this unit, the settings in the shaded cells were selected.
2.5.6
Specifying settings for the lock time for TWAIN operations and for the image in the
results report (mode 023)
Specify the lock time for TWAIN operations and whether or not an image of the transmitted document is
added to the results report.
Factory settings
Specfying the settings
During the production of this unit, the settings in the shaded cells were selected.
Bits
7654 3210
Settings
0001 0001 (HEX: 11)
Bits
Description
Settings
Details
7-6
−
00
*Do not change the settings
for these bits.
5
Specify whether or not a received date report is added dur-
ing mail receptions.
0
Is not added
1
Is added
4
Specify whether the received date report is added outside or
inside of the image during mail reception.
0
Added outside the image
1
Added within the image
3-2
−
00
*Do not change the settings
for these bits.
1
Specify whether or not a received date report is added dur-
ing fax receptions.
0
Is not added
1
Is added
0
Specify whether the received date report is added outside or
inside of the image during fax reception.
0
Added outside the image
1
Added within the image
Bits
7654 3210
Settings
0011 1000 (HEX: 38)
Bits
Description
Settings
Details
7-4
Specify the length of time until machine operations are auto-
matically unlocked with scanning operations.
0000
30 seconds
0001
60 seconds
.
.
.
0011
120 seconds
.
.
.
1001
300 seconds
Others
* Do not specify any settings
other than those mentioned