Clear system-log, Clear timezone, Clear system-log clear timezone – Avaya C460 User Manual
Page 35
Chapter 2 Avaya C460 CLI Commands
Avaya C460 Reference Guide
23
Example:
clear system-log
User level: read-write, admin.
Use the clear system-log command to delete the log file of a Supervisor
Module.
The syntax for this command is:
clear system-log
[
Example:
clear timezone
User level: read-write, admin.
Use the clear timezone command to reset the time zone to its default value UTC
(Coordinated Universal Time)
The syntax for this command is:
clear timezone
Example:
C460-1# clear snmp trap 192.168.173.42
SNMP trap deleted.
spv_num
(Optional)
Number of Supervisor Module (1 to 2)
C460-1# clear system-log
*** Clearing the reset file ***
- do you want to continue (Y/N)? y
C460-1#
C460-1# clear timezone
Timezone name and offset cleared.