Show environment power – Avaya C460 User Manual
Page 164

Chapter 2 Avaya C460 CLI Commands
152
Avaya C460 Reference Guide
show environment power
User level: read-only, read-write, admin.
Use the show environment power command to display the current power
configuration for the switch, the total power available to the system, and amount of
power currently in use.
L The “Main Power” includes two supervisor modules and the fan module,
irrespective of the number of supervisor modules installed.
L The “Main Draw” column shows the demand for an I/O module whether its
slot is enabled or not.
The syntax for this command is:
show environment power
Example:
Total working fans
• 9
• 8
• less than 8
Fans not installed
• No fan tray installed
C460 > show environment power
PSUs Configuration Admin: redundancy
PSUs Configuration State: no redundancy (2 active PSU(s))
Power Available Drawn Remaining
----- --------- ----- ---------
Main 411W 411W 0W
PoE 1589W 0W 1489W
Slot
Module Type
Active Enabled
Priority
Main
Draw
PoE
Budget
PoE
Draw
Fault
----
---------------
------ -------
-------- ----
------
----
-----
1 M460ML-SPV
Y
Y
critical
68W
2 M460ML-SPV
Y
Y
critical
68W
3 M4612ML-G
Y
Y
low
59W
4 M4648ML-T-2G-PWR
Y
Y
high
48W
720W
100W
5 M4648ML-T-PWR
Y
Y
low
48W
720W
0W
6 M4648ML-T-2G
Y
Y
low
70W
* Fans power consumption: 45(W)