Boonton 4540 series rf power meter, Operation – Boonton 4540 Peak Power Meter User Manual User Manual
Page 101
Boonton 4540 Series RF Power Meter
Operation
4-53
Table 4-1
Field Parameter Selection List
Field Parameter
Description
Pulse Width
Automatic Pulse Time Measurement: Pulse width (on time)
Rise Time
Automatic Pulse Time Measurement: Rising edge transition time
Fall Time
Automatic Pulse Time Measurement: Falling edge transition time
Pulse Period
Automatic Pulse Time Measurement: Waveform pulse repetition period
Pulse Rep Freq
Automatic Pulse Time Measurement: Waveform pulse repetition interval
Duty Cycle
Automatic Pulse Time Measurement: Waveform duty cycle
Off Time
Automatic Pulse Time Measurement: Off time between pulses
Pulse Peak Power
Automatic Pulse Power Measurement: Instantaneous Peak Power
Pulse Average Power
Automatic Pulse Power Measurement: Pulse average ―on‖ power
Overshoot
Automatic Pulse Power Measurement: Leading edge overshoot
Waveform Average Power
Automatic Pulse Power Measurement: Power over one full cycle of waveform
Pulse Top Amplitude
Automatic Pulse Power Measurement: IEEE Top Power of pulse
Pulse Bottom Amplitude
Automatic Pulse Power Measurement: IEEE Top Power of pulse
Time Skew
Automatic Edge Delay Measurement: channel-to-channel ―first edge‖ time skew
Edge Delay
Automatic Edge Delay Measurement: ―first edge‖ time offset from start of trace
Channel Frequency
Selected Channel’s RF Frequency setting
Frequency Calfactor
Selected Channel’s currently applied Frequency Calfactor correction
Video Bandwidth
Selected Channel’s video bandwidth setting for peak sensors
Channel Averaging
Selected Channel’s video averaging setting for Pulse Mode
Trigger Settings
Trigger Source, Polarity and Level settings
Trigger Delay
Trigger Delay setting for Pulse Mode
Vertical Scale
Selected Channel’s vertical scale setting for trace display
Vertical Center
Selected Channel’s vertical center setting for trace display
dB Offset
Selected Channel’s gain offset setting in dB
Marker Average
Marker Measurement: Average power over marker interval
Marker Max
Marker Measurement: Maximum instantaneous power over marker interval
Marker Min
Marker Measurement: Minimum instantaneous power over marker interval
Marker MaxFilt
Marker Measurement: Maximum filtered power over marker interval
Marker MinFilt
Marker Measurement: Minimum filtered power over marker interval
Marker Peak/Average
Marker Measurement: Peak-to-Average power ratio over marker interval
Marker 1 Level
Marker Measurement: Average power at marker 1
Marker 2 Level
Marker Measurement: Average power at marker 2
Marker Delta
Marker Measurement: Marker 1 to Marker 2 delta
Marker MaxAvg
Marker Measurement: Highest value of average-between-markers
Marker MinAvg
Marker Measurement: Lowest value of average-between-markers
Marker 1 Min
Marker Measurement: Minimum instantaneous power at marker 1
Marker 1 Max
Marker Measurement: Maximum instantaneous power at marker 1
Marker 2 Min
Marker Measurement: Minimum instantaneous power at marker 2
Marker 2 Max
Marker Measurement: Maximum instantaneous power at marker 2
Marker Ratio
Marker Measurement: Marker 1 to Marker 2 ratio
Marker Rev Ratio
Marker Measurement: Marker 2 to Marker 1 ratio
Marker Rev Delta
Marker Measurement: Marker 2 to Marker 1 delta
Sensor Temp
Selected Sensor’s internal temperature (peak sensors)