Enclosure selection screen – HP Onboard Administrator User Manual
Page 57

First Time Setup Wizard 57
The term FIPS mode used in this document and within the product is to describe the feature, and not its
validation status. The FIPS validation process is lengthy, so not all versions are FIPS validated. For information
about the current FIPS status of this or any other firmware version, see the following documents:
•
Cryptographic Module Validation Program FIPS 140-1 and FIPS 140-2 Modules In Process List
•
FIPS 140-1 and FIPS 140-2 Vendor List
Clear VC Mode
Clearing the VC mode removes all VC settings from the enclosure. Power off all VC-configured servers before
clearing the VC mode. If servers are not powered down, they might maintain the VC settings until they are
rebooted. You must clear the VC mode before changing to the FIPS mode OFF/ON/DEBUG.
To clear the VC Mode:
1.
Click Clear VC Mode. A confirmation screen appears, stating All servers should be powered
off and not configured by Virtual Connect prior to clearing VC mode. Are you
sure that you wish to clear VC mode?
2.
Click OK.
Enclosure Selection screen
The Enclosure Selection screen displays all discovered enclosures and selects the active enclosure (the
enclosure you are signed in to) by default. The check box next to each enclosure enables you to select or clear
that enclosure. To toggle the check box for all enclosures, select the All Enclosures check box.
To update the rack topology information, click Refresh Topology. When you select Refresh Topology, the
Enclosure Selection screen switches to the Linked Mode and all linked enclosures appear.
Linked enclosures have one of the following states:
•
Linked—Not Signed In. Select the enclosure and enter the Administrator password in the password text
box. To authenticate the enclosure, click Next.
•
Linked—Not Signed In with a card reader icon. This state indicates the linked enclosure is Two-Factor
Authentication enabled but is not authenticated. This state occurs under two conditions: