Standby onboard administrator module, Standby onboard administrator screen, Standby onboard administrator virtual buttons tab – HP Onboard Administrator User Manual
Page 192

Configuring the HP BladeSystem c7000 enclosure and enclosure devices 192
Standby Onboard Administrator Module
Standby Onboard Administrator screen
When a second Onboard Administrator is placed in the enclosure, it becomes the Standby Onboard
Administrator. The Standby Onboard Administrator is normally placed in the available Onboard
Administrator tray in the rear of the enclosure. By selecting the Active to Standby screen, you can force a
transition within the Onboard Administrator user interface to make the active Onboard Administrator
become the Standby Onboard Administrator.
For an Active/Standby relationship, the two Onboard Administrator modules must have the same firmware
version installed. If the firmware versions are not identical, the Insight Display and the main status screen of
the Onboard Administrator identifies this error and alerts the user through SNMP if enabled.
If using two Onboard Administrators, each Onboard Administrator has a unique IP address. See the Insight
Display to obtain the IP addresses for the Active and Standby Onboard Administrators and write them down.
When looking at the enclosure from the rear, the bay on the left is bay 1, while the bay on the right is bay
2. When the Active Onboard Administrator transitions to the Standby Onboard Administrator, the DNS host
name and IP addresses remains the same. To connect to the new Active Onboard Administrator, you must
completely close your browser and connect to the host name or IP address of the former Standby Onboard
Administrator.
Status, Information, and Virtual Buttons tabs
The information contained under the Status, Information, and Virtual Buttons tabs is the same as it is for an
Active Onboard Administrator. For information on these tabs, see the "Active Onboard Administrator screen
)."
Standby Onboard Administrator Virtual Buttons tab
Click Reset to reset the Onboard Administrator. A confirmation screen appears, asking if you are sure that
you want to perform the action and that you are signed out and disconnected from the Onboard
Administrator. Click OK to proceed, or click Cancel to exit without a change.
Click Toggle On/Off to change the Onboard Administrator module UID light. This identifies a particular
Onboard Administrator when there are more than one.