Client computer cannot connect, Wl520 has incorrect ip address, Http (browser) or telnet interface does not work – HP ProCurve 520wl Wireless Access Point User Manual
Page 77: Html help files do not appear, Telnet cli does not work, Tftp server does not work
Symptoms and Solutions
5-3
client computer cannot connect
client computer cannot connect
client computer cannot connect
client computer cannot connect
1. Each wireless PC Card in the WL520 unit should have a unique Network Name. This Network Name must match the
active Network Name on client machines. For example the
hp WL520 AP client software allows you to store Network
Names in configuration profiles, then you can select a profile to fit your location.
2. Network Names should be allocated and maintained by the Network Administrator.
3. Refer to the documentation that came with your client card for additional troubleshooting suggestions.
wl520 has incorrect ip address
wl520 has incorrect ip address
wl520 has incorrect ip address
wl520 has incorrect ip address
1. Default IP Address Assignment mode is dynamic (DHCP). If you do not have a DHCP server on your network, the default
IP Address is 10.0.0.1
10.0.0.1
10.0.0.1
10.0.0.1.
2. If the DHCP server in your network is not available for some reason while the WL520 unit reboots, the device will retain
the last IP Address it had. Reboot the WL520 device once your DHCP server is on-line again or use the ScanTool to find
the current IP Address of the WL520 unit in question.
3. To find the current IP Address using DHCP, check the IP Client Table in the DHCP Server to find the current WL520 IP
Address, match to the WL520 MAC Address in the table to the one on your unit.
4. Or use ScanTool to locate the current
Or use ScanTool to locate the current
Or use ScanTool to locate the current
Or use ScanTool to locate the current WL520 IP Address.
IP Address.
IP Address.
IP Address. Once you have the current IP Address, use the HTTP or CLI
Interface to either set the unit to DHCP mode or assign a static IP Address.
5. If you use static IP Address assignments, and cannot access the unit over Ethernet, use the
Initializing the IP Address using
procedure. Once the IP Address is set, you can use the Ethernet Interface to complete configuration.
Reset to Factory Default Procedure
in this guide. This will reset the unit to “DHCP” mode. If there is a DHCP
Server on the same subnet, the DHCP Server will assign an IP Address to the WL520.
http (browser) or telnet interface does not work
http (browser) or telnet interface does not work
http (browser) or telnet interface does not work
http (browser) or telnet interface does not work
1. Make sure you are using a compatible browser: Microsoft Internet Explorer 5.0 or better (preferred), or Netscape 6 or
higher.
2. Make sure you have the proper IP Address. Enter your WL520 IP Address in the browser address bar, similar to this
example:
http://192.168.1.100
http://192.168.1.100
http://192.168.1.100
http://192.168.1.100
When the WL520
Login
window appears, leave
the User Name field empty and enter public
public
public
public in the
Password field.
3. Use the CLI over the serial port to check the SNMP Table, which can be restricting access to Telnet and HTTP.
html help files do not appear
html help files do not appear
html help files do not appear
html help files do not appear
1. Verify that the HTML Help files are installed in the default directory:
C:\Program Files\WL520_AP\AP\Help\
2. If the Help files are not located in this folder, contact your network administrator to find out where the Help files are located
on your server.
3. Perform the following steps to verify or enter the pathname for the Help files:
a. Click the
Help
Help
Help
Help
button in the Web Interface.
b. Select the
Help Link
Help Link
Help Link
Help Link
tab located at the top of the screen.
c. Enter the pathname where the Help files are located.
d. Click
OK
OK
OK
OK
when finished.
telnet cli does not work
telnet cli does not work
telnet cli does not work
telnet cli does not work
1. Make sure you have the proper IP Address. Enter your WL520 IP Address in the Telnet connection dialog, from a DOS
prompt, type:
C:\> telnet <
WL520 IP Address>
2. Use the CLI over the serial port to check the SNMP Table, which can be restricting access to Telnet and HTTP.
tftp server does not work
tftp server does not work
tftp server does not work
tftp server does not work
1. Make sure the TFTP Server has been started.
2. Verify the IP Address of the TFTP Server. The server may be local or remote, so long as it has a valid IP Address.
3. Configure the TFTP Server to “point” to the folder containing the file to be downloaded (or to the folder in which the file is
to be uploaded).
4. Verify that you have the proper WL520 Image file name and directory path.