Virtual connect documentation – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 9
Introduction 9
o
The HP ProLiant BL460c Gen8 Server Blade
o
The HP FlexFabric 10Gb 2-port 534FLB Adapter
o
The HP FlexFabric 10Gb 2-port 534M Adapter
o
The HP QMH2672 16Gb FC HBA for BladeSystem c-Class
•
VCEM compatibility:
o
VCEM requires IPv4 connectivity to manage Virtual Connect.
o
If you are running VCEM 6.3.1 or later to manage a VC 4.10 domain, the 4.10 domain can be in
a VCDG in 3.30 firmware mode or later. To enable new features in VC 4.10, you must upgrade to
VCEM 7.2.2 or later. VCEM 7.2.2 does not support VC versions prior to 3.30.
o
VCEM does not manage VC domains configured for auto-deployment.
o
Configurable role operations must be delegated to one of the following roles if they are to be
performed while the domain is in Maintenance Mode: Network, Storage, or Domain.
Administrators logging into VCM with a Server role account while the domain is in Maintenance
mode will be denied access to perform delegated operations such as exporting support files,
updating firmware, configuring port monitoring, or saving or restoring domain configuration.
o
In VC 4.10, the telemetry port throughput is Enabled by default. You must do the following to add
a fresh VC 4.10 installation to your existing VCDG:
—
3.30-3.70 VCDG with statistics throughput disabled—Clear the Enable Throughput Statistics
check box on the Ethernet Settings (Advanced Settings) screen ("
" on page
), or run the following VCM CLI command:
set statistics-throughput Enabled=false
—
3.30-3.70 VCDG with statistics throughput enabled—Add the domain as is. No change is
required.
o
In VC 4.10, the VLAN Capacity is set to Expanded by default. You must do the following to add a
fresh VC 4.10 installation to your existing VCDG:
—
3.30-3.70 with Legacy VLAN VCDG—You cannot add the domain. Select a different VCDG.
—
3.30-3.70 with Enhanced VLAN VCDG—Add the domain as is. No change is required.
•
A server profile migration of a SAN-booted server between enclosures is not supported for SAN-boot
from a Direct-Attached 3PAR array.
•
The FTP service is disabled by default. The VCSU software temporarily enables it as necessary during
firmware upgrades.
Virtual Connect documentation
The following Virtual Connect documentation is available on the Installing tab of the HP BladeSystem
Technical Resources website
•
HP Virtual Connect for c-Class BladeSystem User Guide
This guide provides details for the Virtual Connect GUI, including descriptions of screen contents and
steps to set up domains, profiles, networks, and storage.
•
HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide
This guide provides hardware installation and configuration information for initial setup of a Virtual
Connect solution. The guide also provides Virtual Connect module component and LED descriptions
and guidelines for module installation and upgrades.