HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 148

background image

Virtual Connect fabrics 148

Column

Description

FabricAttach. Select FabricAttach if the FlexFabric module is connected using

traditional SAN switches. For this fabric type, the advanced settings appear, allowing

you to change the login re-distribution and set the preferred and maximum connection

speed. Select DirectAttach if the FlexFabric module is directly connected to a supported
storage target. Login re-distribution is not applicable for a DirectAttach fabric;

however, advanced settings are available for the preferred and maximum connection

speed. After a fabric is defined, its type cannot be changed.

Login Re-Distribution

Login Re-distribution setting for the fabric. For all standard VC-FC modules, this is

always Manual. For FlexFabric modules, this can be set as described in "Login

re-distribution (on page

149

)" when the fabric type is set to FabricAttach.

Configured Speed

Speed of the uplink ports, available after a port has been added. Valid values once
allowed are 2Gb, 4Gb, 8Gb, and Auto. If 8Gb is chosen for the uplink speed on an FC

module that does not support 8Gb, the value is automatically translated to "Auto"

within VCM. This allows the module to connect at the highest supported speed.

Uplink Port

Number of the FC module uplink port

Enclosure

Enclosure selected for the SAN fabric.

Bay

Enclosure bay selected for the SAN fabric. Only uplinks on the same bay can be in the

same SAN fabric.

Port Status

Shows the link status, link speed, and connectivity of the port. If the port is unlinked and

no connectivity exists, the cause is displayed. For more information about possible
causes, see "Port status conditions (on page

261

)."

Speed

Port speed for the uplink ports in the fabric

Connected To

WWN of the principal switch on the SAN fabric that this port is connected to on the

other end

Action

Perform delete operations

The following table describes the available actions in the Define SAN Fabric screen. Clicking another link in

the pull-down menu or left navigation tree causes the current edits that have not been applied to be lost.

Task

Description

Create a fabric name

Type a name in the Fabric Name field. Do not use spaces.

Add an uplink port

Select a bay and port from the Add Port cascading menu. In

double-dense mode, do not select Bay 7 or Bay 8.

Set the uplink port speed

After an uplink port has been added, click the pull-down arrow in the
Configured Speed field, and then select a speed. The default value is

Auto, which auto-negotiates the speed with the FC switch to which the

ports are connected. If 8Gb is chosen for the uplink speed on an FC
module that does not support 8Gb, the value is automatically translated

to "Auto" within VCM. This allows the module to connect at the highest

supported speed.

Set the fabric type

After a FlexFabric module port has been added, click the pull-down

arrow in the Fabric Type field, and then select a fabric type. The default

value is FabricAttach, which indicates that the module is connected using

traditional SAN switches.

Set the login re-distribution

After a FlexFabric module port has been added, select the Show

Advanced Settings checkbox, and then select manual or automatic. For

more information, see "Login re-distribution (on page

149

)."