Multiple enclosure requirements – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 61
HP BladeSystem c-Class enclosures 61
The management interfaces for all enclosure Onboard Administrators and VC modules within the same VC
domain must be on the same lightly loaded subnet and highly reliable network. Overloads or loss of
connectivity can disable configuration attempts until the connectivity is re-established and synchronized with
the domain. The Onboard Administrator IP addresses used must be configured to be static. The Onboard
Administrator user credentials for all enclosures must be consistent to enable VCSU firmware updates for VC
modules in the remote enclosures. All FC-capable modules in the same horizontally adjacent bay pair (bays
1-2, 3-4, and so on) must be of the same type and position in all enclosures.
Multi-enclosure double-dense domains require similar and compatible VC-FC modules in bays 5, 6, 7, and
8 in all enclosures if FC connectivity is required. If a multi-enclosure double-dense configuration contains
incompatible VC-FC modules in bays 5, 6, 7, or 8 in the local or remote enclosures, some or all of the
compatible VC-FC modules in the remote enclosures might be designated INCOMPATIBLE after import.
For multi-enclosure domains using Direct Attach Storage, a server profile migration of a SAN-booted server
between enclosures is not supported.
Multiple enclosure requirements
Observe the following requirements when connecting multiple enclosures:
•
Each enclosure must have at least one supported VC-Enet module installed.
•
All VC-Enet modules must be interconnected (redundantly stacked).
•
All enclosures must have the same FC and FlexFabric module configuration. For example, if bays 1 and
2 of the Primary Enclosure contain FlexFabric modules, then bays 1 and 2 of Remote Enclosures 1, 2,
and 3 must also contain FlexFabric modules.
•
All enclosures must have the same HP VC Flex-10/10D module configuration. For example, if bays 1
and 2 of the Primary Enclosure contain HP VC Flex-10/10D modules, then bays 1 and 2 of Remote
Enclosures 1, 2, and 3 must also contain HP VC Flex-10/10D modules.
•
A single domain supports up to four c7000 enclosures.
•
When using multiple c7000 enclosures, the number of modules supported across the enclosures within
a domain is limited. A total of 16 Ethernet and 16 VC-FC type modules can be installed, with a
maximum of 4 VC-Enet or 4 VC-FC modules per enclosure. A FlexFabric module counts as 1 Ethernet
and 1 VC-FC module. Thus, up to 16 FlexFabric Modules or combinations of FlexFabric, VC-Enet, and
VC-FC modules are allowed as long as the 16-module limit for each module type (Ethernet and FC) is not
exceeded in the domain.
•
All Onboard Administrators and VC modules must be on the same lightly loaded and highly reliable
management Ethernet network and IP subnet.
•
The VC-FC and FlexFabric FC-configured uplink port configuration must be identical across all
enclosures.
•
The Onboard Administrator firmware must be version 3.11 or higher. HP recommends using the latest
version available. Using IPv6 requires OA 4.00 or higher.
•
All Onboard Administrators must use the same user credentials because VCSU uses the primary
credentials for the remote enclosure.
•
When both Primary and Standby modules in the base enclosure are taken down for maintenance or
lose power and are no longer present in the domain, the management capabilities in the VC domain
are lost. If network and fabric uplinks are defined on the remaining enclosures, the servers continue to