HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 35
Virtual Connect domains 35
Trap
Category
Severity
MIB
vcFcFabricManagedStatusChanged
3
VCM Fabric Status
Corresponds to the
name of the new state
VCD-MIB
VC module status change (deprecated) —
—
—
vcModuleManagedStatusChanged
3
VC-Enet Module Status or
VC-FC Module Status
Corresponds to the
name of the new state
VCD-MIB
Profile status change (deprecated)
—
—
—
vcProfileManagedStatusChanged
3
VCM Profile Status
Corresponds to the
name of the new state
VCD-MIB
Physical server change (deprecated)
—
—
—
vcPhysicalServerManagedStatusChang
ed
3
VCM Server Status
Corresponds to the
name of the new state
VCD-MIB
vcTesttrap
VCM Domain Status
INFO
VCD-MIB
Enet IF-MIB LinkDown
VC-Enet Port Status
INFO
IF-MIB
Enet IF-MIB LInkUp
VC-Enet Port Status
NORMAL
IF-MIB
Input utilization above high-water mark² VC-Enet Port Threshold
WARNING
VCM-MIB
Input utilization below low-water mark² VC-Enet Port Threshold
NORMAL
VCM-MIB
Output utilization above high-water
mark²
VC-Enet Port Threshold
WARNING
VCM-MIB
Output utilization below low-water
mark²
VC-Enet Port Threshold
NORMAL
VCM-MIB
Input errors above high-water mark²
VC-Enet Port Threshold
WARNING
VCM-MIB
Input errors below low-water mark²
VC-Enet Port Threshold
NORMAL
VCM-MIB
Output errors above high-water mark² VC-Enet Port Threshold
WARNING
VCM-MIB
Output errors below low-water mark²
VC-Enet Port Threshold
NORMAL
VCM-MIB
vcModPortBpduLoopDetected
VC-Enet Port Status
CRITICAL
VCM-MIB
vcModPortBpduLoopCleared
VC-Enet Port Status
INFO
VCM-MIB
vcModPortProtectionConditionDetected VC-Enet Port Status
CRITICAL
VCM-MIB
vcModPortProtectionConditionCleared VC-Enet Port Status
INFO
VCM-MIB
¹ Only supported by the HP VC 8Gb 24-Port FC module
² The VC Module MIB has the capability to send traps when certain bandwidth and throughput utilization thresholds are
reached. The counters are sampled at a fixed interval of 30 seconds and neither sample interval nor threshold values are
configurable in this release. Thresholds are defined as follows:
— Port utilization high water mark 95%
— Port utilization low water mark 75%
— Errors high water mark 5%
— Errors low water mark 1%
For more information, see the description field in the source code for individual MIBs.
3
For more information, see "VC Domain Managed Status Changed traps (on page
)."
IMPORTANT:
During OA failover or other management network disruptions, VC SNMP traps
might not reach the management station.
The VC-FC module generates connUnitPortStatusChange traps based on changes to the connUnitPortStatus
element of the FA-MIB. The following table shows the mapping of connUnitPortStatusChange trap severities
to the VC Domain MIB's trap severity definitions.
connUnitPortStatus value
Severity
unknown
INFO
unused
INFO