HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 232
Virtual Connect modules 232
Ethernet Bay Summary (Uplink Port Information) screen
This screen provides a summary of the interconnect module uplink port information. To remove a module, see
"Interconnect module removal and replacement (on page
)."
The following table describes the columns within the Uplink Port Information (Enet) table.
Column
Description
Label
Uplink port number
Network(s)
Network name or the name of the shared uplink associated with this port
Status
Shows the link status, link speed, and connectivity of the port. If the port is
unlinked and no connectivity exists, the cause is displayed. For more
information about possible causes, see "Port status conditions (on page
)."
Connector Type
Displays the physical type of the faceplate connector, type of pluggable
module if one is present, or "Internal" to indicate the inter-switch link is active
on the VC-Enet module.
LAG ID
Identifies the group of ports that have been aggregated together to form an
802.3ad Link Aggregation Group. This ID is unique only within a single
VC-Enet module, meaning the same LAG ID can be used on different VC-Enet
modules, but it is only meaningful for ports within the same VC-Enet module.
Connected To
Displays the switch LLDP system name or management IP address of the device
that this port is connected to on the other end. The remote device must support
LLDP to display this information.
Detailed Stats / Info ("
Port Detailed Statistics screen
Click to display detailed statistics about this Ethernet port.
The following table describes the columns within the Uplink Port Information (FC) table.