Module reason code

Description

vcEnetmoduleEnclosureDown

The module is unable to communicate with the enclosure/OA.

vcEnetmoduleModuleMissing

A configured module has been removed.

vcEnetmodulePortprotect

A condition has been detected on the port causing port protection to

be activated.

vcEnetmoduleIncompatible

The module is incompatible, for example, a configured Enet module
is replaced with an FC module.

vcEnetmoduleHwDegraded

The module is being reported as degraded by the OA.

vcEnetmoduleUnknown

The condition of the module is unknown.

vcFcmoduleOk

The FC module is functioning normally.

vcFcmoduleEnclosureDown

The FC module is unable to communicate with the enclosure/OA.

vcFcmoduleModuleMissing

A configured module has been removed.

vcFcmoduleHwDegraded

The module is reporting a degraded hardware condition.

vcFcmoduleIncompatible

The module is incompatible, such as replacing a configured FC

module with an Enet module.

vcFcmoduleUnknown

The condition of the module is unknown.

vcPhysicalServerManagedStatusChanged
The following is an example of a physical server Cause string:

Server enc0:dev1 unable to communicate with enclosure enc0

The following is an example of a physical server RootCause string:

Server enc0:dev2 profile pending

The physical server managed status ReasonCodes are provided in the following table.

Physical server reason code

Description

vcPhysicalServerOk

The server is functioning normally.

vcPhysicalServerEnclosureDown

The server is unable to communicate with the enclosure/OA.

vcPhysicalServerFailed

The server is in a failed condition.

vcPhysicalServerDegraded

The server is in a degraded condition.

vcPhysicalServerUnknown

The condition of the server is unknown.

vcFcFabricManagedStatusChanged
The following is an example of a FC fabric Cause string:

1 of 2 uplink ports are abnormal on BackupSAN fabric

The following is an example of a FC fabric RootCause string:

1 of 2 uplink ports are abnormal on BackupSAN fabric

The FC fabric managed status ReasonCodes are provided in the following table.

FC fabric reason code

Description

vcFabricOk

The fabric is functioning normally.

vcFabricNoPortsConfigured

The fabric does not have any uplink port configured.

vcFabricSomePortsAbnormal

Some uplink ports for the fabric are in an abnormal condition.

vcFabricAllPortsAbnormal

All uplink ports for the fabric are in an abnormal condition.

vcFabricWwnMismatch

A WWN mismatch condition has been detected.

vcFabricUnknown

The condition of the fabric is unknown.