beautypg.com

HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 194

background image

Virtual Connect server profiles 194

If the 'Force same VLAN mappings as Shared Uplink Sets' option is selected, server VLAN mappings are the

same as the shared uplink set VLAN mappings. You can choose only from a list of shared uplink sets when
selecting Multiple Networks. After selecting a shared uplink set from the pull-down list, a list of VLANs that

belong to the chosen shared uplink set is displayed.
The server VLAN mappings are the same as those used on the shared uplink set, which are automatically

displayed and cannot be changed. One of the networks can also be selected as the 'Untagged' network,
which means that untagged packets are placed on that VLAN, and the VC-Enet module also transmits

untagged packets to the server for that network.
With this 'forced' option selected, the server connection VLAN mappings are linked to the chosen shared

uplink set. Any change to the uplink VLAN mappings is reflected automatically on the server connection using
those shared uplink set VLAN mappings. Therefore, to minimize network outage time, any VLAN mapping

changes to the uplinks requires immediate changes being made to the VLAN tagging on the servers.

No Forced VLAN Mappings
If the 'Force same VLAN mappings as Shared Uplink Sets' option is not selected, you can choose available

networks and assign a unique server VLAN associated with the network for this server port. Not forcing VLAN
mappings provides greater flexibility in selecting the set of networks to connect to each server port, and

enables administrators to specify server VLAN mappings independent of those assigned by the network

administrator for the shared uplink sets. The untagged option is always available, but it might be unassigned,

that is, any untagged frame from the server is dropped. Each network can be selected only once per server
port. Similarly, each server-assigned VLAN must be unique per server port.
This option is not available if the domain-wide 'Force server connections to use the same VLAN mappings as

shared uplink sets' checkbox on the Advanced Settings tab of the Ethernet Settings screen is selected.
If the selected network is part of a shared uplink set, it has an associated external VLAN mapping. This
external VLAN is used to pre-populate the server-assigned VLAN entry to maintain consistency throughout the

VC domain. However, multiple networks on different shared uplink sets can have the same external VLAN

mapping. If those networks are selected for the same server port, you must edit the server VLAN to ensure all

VLANs are unique for each server port.