HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 39
Virtual Connect domains 39
Modules not redundantly connected, failure of module enc0:iobay1 or
enc0:iobay2 or enc1:iobay2 will isolate some modules; Port enc0:iobay5:d3:v1
loop detected and automatically disabled
The domain managed status ReasonCodes are provided in the following table.
Domain reason code
Description
vcDomainOk
All enclosures and profiles are normal in the domain.
vcDomainAbnormalEnclosuresAndProfil
es
One or more enclosures and profiles are abnormal in the domain.
vcDomainSomeEnclosuresAbnormal
At least one enclosure is not OK or Degraded.
vcDomainUnmappedProfileConnections The profile contains connections that are not mapped to a server port.
vcDomainStackingFailed
All stacking links between one or more modules have failed.
vcDomainStackingNotRedundant
Some stacking links between one or more modules have failed, but
connectivity still exists between modules.
vcDomainSomeProfilesAbnormal
One or more profiles in the domain are abnormal.
vcDomainUnknown
The condition of the domain cannot be determined.
vcDomainOverProvisioned
More than 16 VC modules are in the domain.
vcEnclosureManagedStatusChanged
The following is an example of an enclosure Cause string:
2 of 6 Ethernet modules are abnormal in enclosure enc0
The following is an example of an enclosure RootCause string:
Module in bay enc0:iobay3 has been removed
The enclosure managed status ReasonCodes are provided in the following table.
Enclosure reason code
Description
vcEnclosureOk
The enclosure is normal.
vcEnclosureAllEnetModulesFailed
All Ethernet modules are abnormal, none are OK or degraded.
vcEnclosureSomeEnetModulesAbnormal One or more Ethernet modules are abnormal.
vcEnclosureSomeModulesOrServersInco
mpatible
The enclosure contains incompatible modules, or configured modules
are missing.
vcEnclosureSomeFcModulesAbnormal
One or more FC modules are abnormal.
vcEnclosureSomeServersAbnormal
At least one server is in a known state and no servers are OK, or at
least one server is degraded.
vcEnclosureUnknown
The condition of the enclosure cannot be determined, or the state of
servers or modules is unknown.
vcModuleManagedStatusChanged
The following is an example of a module Cause string:
Port enc0:iobay5:d3:v1 loop detected and automatically disabled
The following is an example of a module RootCause string:
Port enc0:iobay5:d3:v1 loop detected and automatically disabled
The module managed status ReasonCodes are provided in the following table.
Module reason code
Description
vcEnetmoduleOk
The Ethernet module is functioning normally.