2.1.7.4 SL2x170z G6 and DL170h G6 Servers BIOS setting

IMPORTANT:

To enable BIOS updates, you must restart the server. You can restart the server

with Ctrl+Alt+Delete immediately after leaving the BIOS, or you can physically restart the server
by using the power switch on the server.

Figure 3 NIC2 on the SL2x170z G6 Server

BIOS settings

Post speedup Enabled

Numlock Enabled

Restore after AC loss Last state

Post F1 prompt Delayed

CPU setup

Proc hyper threading Disabled

IDE configuration

SATA controller mode AHCI

Drive cache Enabled

IDE timeout 35

Chipset ACPI configuration

High Performance Event timer Enabled

IPMI serial port configuration

Serial port assignment BMC

Serial port switching Enabled

Serial port connection mode Direct

LAN configuration

If your node is wired with the LO100i management port shared with NIC2:

BMC NIC Allocation Shared

LAN protocol: HTTP, telnet, ping Enabled

18