5 parameters, P547 digital bus setpoint 2, P548 digital bus setpoint 3 – NORD Drivesystems BU0060 User Manual
Page 85: P551 drive profile, P560 parameter, saving mode

5 Parameters
BU 0060 GB-4112
85
P547
Digital Bus setpoint 2
(Function of bus setpoint 2)
S
P
0 ... 55
{ 0 }
This parameter is identical to P546.
Pos : 158 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P548 – Funkti on Bus-Soll wert 3 [ SK 500... 535E] @ 0\ mod_1328098278323_388. doc x @ 11985 @ @ 1
P548
Digital Bus setpoint 3
(Function of bus setpoint 3)
S
P
0 ... 55
{ 0 }
This parameter is identical to P546.
Pos : 159 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P551 – Antriebs profil @ 0\ mod_1328098517139_388. doc x @ 12054 @ @ 1
P551
Drive profile
(Drive profile)
S
0 … 1
{ 0 }
According to the option the relevant process data profiles can be activated with this parameter.
Note
Activation of profiles
This parameter is only effective for pluggable technology modules (SK TU3-…).
System
CANopen
DeviceNet
InterBus
Technology module
SK TUx-CAO
SK TUx-DEV
SK TUx-IBS
Setting
0 = OFF =
USS protocol (Profile "Nord")
1 = ON =
DS402 profile
AC Drives profile
Drivecom profile
Pos : 160 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P560 – Paramet er Speic hermode @ 0\ mod_1328098918376_388. doc x @ 12238 @ @ 1
P560
Parameter, Saving mode
(Saving mode parameter)
S
0 ... 2
{ 1 }
0 = Only in RAM, changes to the parameter settings are no longer saved on the EEPROM.
All previously saved settings are retained, even if the FI is disconnected from the mains.
1 = RAM and EEPROM, all parameter changes are automatically written to the EEPROM
and remain stored there even if the FI is disconnected from the mains supply.
2 = OFF, no saving in RAM and EEPROM possible (no parameter changes are accepted)
NOTE: If BUS communication is used to implement parameter changes, it must be ensured
that the maximum number of write cycles (100,000 x) in the EEPROM is not
exceeded.
Pos : 161 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ P7xx I nf or mationen @ 0\ mod_1328170311705_388. doc x @ 12293 @ 5 @ 1