beautypg.com

7 installation of the sk cu1-xxx customer unit, Installing the customer unit, Installation of the sk cu1-xxx customer unit – NORD Drivesystems BU0060 User Manual

Page 28: Warning, Electric shock, Error message e017

background image

CANopen – Supplementary manual options for NORD - Frequency Inverters

28

BU 0060 GB-4112

2.2.7 Installation of the SK CU1-xxx customer unit

WARNING

electric shock

Modules must not be inserted or removed unless the device is free of voltage. The slots may only be used for
the intended modules. Installation remote from the frequency inverter is not possible. It must be connected
directly to the frequency inverter.

Failure to comply with this may result in an electric shock, which my cause serious injury and the destruction of
the frequency inverter and the module.

Note

Error message E017

Following the insertion, replacement or removal of modules, and once the equipment has been switched on
again, this procedure is indicated with the message E017 Customer unit changed.

This message can be directly reset by the usual measures.

Installing the customer unit

1. Switch off the mains voltage, observe

the waiting period.

2. Remove the cover grille from the

connection area by loosening the 2
screws and levering out the device
cover (slot) or simply pull it out.

3. Locking lever in the "„open“ position.

4. Using light pressure push the

customer unit into the upper guide rail
until it engages.

5. Locking lever in the „closed“ position.

6. Remove the connector by pressing the

releases then make the necessary
connections. Then insert the
connectors until they engage.

7. Replace all covers.

Kundenschnittstelle

Sondererweiterung

Technologiebox

Verrieglungsstift

CLOSED

OPEN

Verriegelung geschlossen

Verriegelung geöffnet

Customer

interface

Special

extension

Technology unit

Locking lever

Lock closed

Lock open