Installation and Operating Instructions OPTIMASS

82

Cyclic Display Fct. 3.2.1

The display can be programmed to cycle between all values or to remain static at the selected variable.

To select an option:

Display

Key

Line 1

Line 2

From

Fct. 3.2.1

Cycle Disp.

STATIC DISPLAY

CYCLE DISPLAY

STATIC DISPLAY

Press ↵ to select the required option.


Mass Flow Fct. 3.2.2

The units and the measurement resolution can be set in this menu.

Display

Key

Line 1

Line 2

From

Fct. 3.2.2

Mass Flow.

00000.000

(kg) / min

Changes the eng. units selectable kg, t, oz, Ib, g.

When unit selected press → to select time base. kg / (min)

Changes the time units selectable min, hr, day, sec.

When time unit selected press → . This will now allow the selection of the decimal position.

Press ↑ to select the decimal position.

When selection complete press ↵.


Mass Total Fct. 3.2.3

This menu allows the setting of the units for the mass totalizer.

Display

Key

Line 1

Line 2

From

Fct. 3.2.3

Mass Flow.

00000.000 (kg)

The ↑ selects the units. Choose from kg,t,oz,Ib,g.

now allows the decimal position to be selected.

Shifts the decimal position.

When selection complete press ↵.


Volume Flow Fct. 3.2.4

Allows the selection of volume flow and the associated units.

Display

Key

Line 1

Line 2

From

Fct. 3.2.4

Volume Flow.

(off) – default is off.

00000.000 (cm³)/sec

Selects the units. Selection of cm³, dm³, litre, m³, in³, ft³, US gal,

Impgal, off.

Allows the setting of the time base. Selection of sec, min, hr,

day.

When selection complete press ↵.