Installation and Operating Instructions OPTIMASS

27

1.3.8 Technical Data

Nominal Flow Rates

01

03

04

Kg/h

15 100 350

Lbs/min

0.5 3.5 12.5


Maximum flow rate

Typically 130 % of the nominal flow rate for the sensor size depending on application.


Minimum flow rate

Depending on measuring error required.


Tube materials:

S 316L

Hastelloy C22

The meter size has a prefix S or H indicating the tube material.


Secondary pressure containment

All OPTIMASS 3000 (7100) Series meters have secondary containment rated to 30 bar or 435 psi.


Materials of construction


Connections: SS 316 L or HC22

Secondary Containment: SS 316 L

Front end housing and post: SS 316 L

Converter housing: Epoxy coated aluminium