beautypg.com

3 mechanical installation 3000.pdf – KROHNE OPTIMASS with MFC 05x EN User Manual

Page 24

background image

Installation and Operating Instructions OPTIMASS

23

1.3 OPTIMASS 3000 (7100) Single Z Shaped Tube Meter

1.3.1 Specific Installation Guidelines
When installing, please observe the following:

Four holes are provided in the base plate and all four should always be used.

The plastic inserts in the base plate mounting holes are important to ensure a rigid and stable

connection to the mounting structure.

It is important to mount on a firm and rigid structure to obtain a stable zero condition.

The following guidelines are provided to assist the installer to select the best option:

Flow

Vertical mount is possible.

Horizontal mount is possible.

.

Flow

Take care to avoid gas build up in top half of tube

bends.

Do not suspend from flanges alone. Base must

always be supported.


Do not install upside down