KROHNE OPTIMASS with MFC 05x EN User Manual
Page 68
Installation and Operating Instructions OPTIMASS
67
4.5 Reset / Quit Menu - Totalizer reset and status indication acknowledgement
Totalizer reset
Button Display
Description
10.36
kg
Measurement mode
↵
CodE 2
––
Enter access Code 2 for reset/quit menu:
↑ →
↑ →
RESET.TOTAL
Totalizer reset menu
If the additional totaliser is selected (Fct. 3.1.6) a choice of reset
options is presented:
* RESET ALL
Reset all totalisers
* ADDITIONAL
Reset only the additional totaliser
Otherwise the following is presented:
* SURE YES
* SURE NO
Note:
The reset option can be disabled by Fct. 3.5.3 or Custody
Transfer (CT) lock.
View status message(s) and quit
Button Display
Description
0.36
kg/min
∇
Measurement mode
The presence of the
∇ marker above Status on the display
indicates the presence of warning messages in the status list.
↵
CodeE 2
– –
∇
Enter access code for reset/quit menu:
↑ →
↑→
RESET.TOTAL
∇
Totalizer reset menu.
↑
STATUS.LIST
∇
View/Quit Status message menu
→
MASS FLOW
∇
Use either the
↑ or → keys to view other messages in the list.
Otherwise press
↵ to exit.
→
QUIT YES
∇
At the end of the message list the QUIT YES prompt is shown.
Selecting YES will clear if possible messages in the list.
To cancel the operation press
↑ to get QUIT NO and then press
↵.
↵
STATUS.LIST
Assuming the conditions that caused the message have passed
(i.e. mass flow is back within the meter’s range) then the Status
marker,
∇ will disappear.
↵
Returns to measuring mode.
An overview with typical status messages and descriptions will be given in the table in chapter 6.2.
View FE Status
Button Display
Description
↵
CodeE 2
– –
Enter access code for reset/quit menu:
↑ →
↑
↑
RESET.TOTAL
STATUS.LIST
FE STATUS
Totalizer reset menu.
View/Quit Status message menu
View FE Status messages
→
Messages
Normally no messages are present.
Further messages are sometimes present which indicate the
various diagnostic indicators, primarily for service or trouble
shooting purposes.