KROHNE OPTIMASS with MFC 05x EN User Manual
Page 62
Installation and Operating Instructions OPTIMASS
61
Fct.
No
Text Description
and
settings
3.2.11 CONC.BY.VOL. Monitor concentration by volume
* Select OFF (no concentration by volume on display or
* PERCENT V
3.2.12 VELOCITY
Monitor flow velocity
* Select OFF (no flow velocity on display or)
* m/sec
* ft/sec
3.2.13 LANGUAGE
Language for display text
* ENGLISH
* FRANCAIS
* ESPANOL
* DEUTSCH
3.3
CONC. MEAS.
Submenu 3.3 Concentration measurement
3.3.1
CONC. MODE
* NOT FITTED (no concentration measurement available) or select option (only if
concentration was ordered):
* NONE
* BRIX
* GEN. CONC.
* BAUME 144.3
* BAUME 145.0
* NAOH
* PLATO
3.3.2
ENABLE.CONC Enter the access code for concentration measurement
If access is enabled:
3.3.2 OFFSET
Offset for concentration measurement
Input manual concentration offset
* Direct input of a concentration offset.
3.3.3 CONC
TYPE
3.3.4 CONC
CF1
3.3.12 CONC
CF12
Refer to separate concentration manual
3.4 DENSITY
Submenu
3.4
Density
3.4.1 DENS.
MODE Option density mode
Press key
↵ , select with key → and ↑ unit and value, quit with key ↵ back to function
3.1.5.
FIXED (Norm density)
REFERRED (temperature-referred density)
ACTUAL (operating density)
3.4.2 FIXED
Input of the fixed density for the option „FIXED“ only
3.4.2 REF
TEMP
Input of the reference temperature for the option „REFERRED“ only
3.4.3 SLOPE
Input of the slope for the option „REFERRED“ only
3.5 PASSWORDS
Submenu
3.5
Passwords
3.5.1 SUPERVISOR Supervisor code for accessing menus required?
Use the key
↑ to select, then press ↵.
* ENABLE PW
* CHANGE PW (set a 9-keystroke code)
* EXIT
Default setting:
→ → → ↵ ↵ ↵ ↑ ↑ ↑
3.5.2 CUSTODY
Custody transfer code required?
3.5.3 TOTAL.RESET Totaliser reset enabled?
Use the key
↑ to select, then press ↵.
* ALLOW.RESET (reset unblocked)
* COMM RESET (reset via communication options is enabled)
* NO RESET (reset blocked)
3.6 SETTINGS
Submenu
3.6
Settings
3.6.1 TAG
ID.
Tag name setting
(measuring point number)
Required only for flow meters using the MIC 500 Hand Held Communicator (HHC),
connected to current output)..
Factory setting: ”MFC 050 (or MFC 51)”
Characters assignable to each place:
A...Z / 0...9 / + / - / * / = / // ( > = blank character)