59

Fct.
No

Text Description

and

settings

2

TEST

Main Menu 2. Test functions

2.1

DISPLAY.

Carry out display test
* SURE (NO). Use the

↑ key to select YES, then press ↵ (Duration of test approx.

30 sec.). Stop test at any time with the

↵ key.

2.2

CUR. OUT. 1

Test current output I
* SURE (NO). Use the

↑ key to select YES, then press ↵. Use the ↑ key to select

test signals from the list below.
0 mA

2 mA 12 mA

16 mA 20 mA 22 mA

To exit test mode, press the

↵ key at any time.

2.3

CUR. OUT. 2

Test current output 2
see CUR. OUT. 1 above

2.4

CUR. OUT. 3

Test current output 3
see CUR. OUT. 1 Fct. 2.2 above

2.5 PULSE

OUT. Test frequency output

* SURE (NO). Use the

↑ key to select YES ,then press ↵. Use the ↑ key to select desired

pulse width from the list below:
∗ 0.05 mSec ∗ 0.4 mSec ∗ 1.0 mSec
∗ 10.0 mSec ∗ 100.0 mSec ∗ 500.0 mSec
Then press

↵. The system now sends pulses of the required width. To stop the test press

↵ twice.

2.6 FREQ.

OUT. Test frequency output

* SURE (NO). Use the

↑ key to select YES ,then press ↵.

* LEVEL LOW 0 volt DC level will be output from the converter.
Use the

↑ key to select test signals from the list below.

* LEVEL HIGH (+ V volts dc)
* 1 Hz

* 100 Hz

* 10 Hz

* 1000 Hz

2.7 ALARM

OUT. Test alarm output

* SURE (NO). Use the

↑ key to select YES, then press ↵

* LEVEL LOW. 0 Volts is output on the alarm terminal.
Press the

↑ key to switch output to:

* LEVEL HIGH . +24V dc is output on the alarm terminal.
To exit test mode, press the

↵ key at any time.

2.8 CONTROL.INP

Test control input
* SURE (NO). Use the

↑ key to select YES, then press ↵.

The actual input level, HI or LO, and the selected functions are displayed see Fct. 3.6.1
End test by pressing the

↵ key.

2.9 DIAGNOSE Submenu

2.9

Diagnose

2.9.1 TUBE

TEMP. Test temperature

Start with the

→ key. The temperature in °C or °F is displayed.

Use the

↑ key to display the temperature in °F.

End the test by pressing the

↵ key.

2.9.2 STRAIN

M.T. Test strain measuring tube

Start with the

→ key. The strain resistance in Ohms is displayed. End the test by pressing

the

↵ key.

2.9.3 STRAIN

I.C.

Test strain inner cylinder
Start with the

→ key. The strain resistance in Ohms is displayed. End the test by pressing

the

↵ key.

2.9.4 TUBE

FREQ. Monitor the primary head frequency

Start test with the

→ key. End the test with the ↵ key.

2.9.5 DRIVE.ENEGY. Monitor the primary head's drive level

Start test with the

→ key. End test with the ↵ key.

2.9.6 SENSOR

A

2.9.7 SENSOR

B

Monitor the amplitudes of sensor A and B
as percentage of their max. value.
Value should correspond to amplitude setting in Fct. 5.2.4
Start test with the

→ key. End the test with the ↵ key.

2.9.8 COMM.ERROR

S

Monitor communication errors
Start test with the

→ key. Number of communication errors since power on is displayed.

End the test with the

↵ key.

2.10

VERSIONS

Submenu 2.10 Versions


2.10.1

BACKEND.SW

Monitor the backend software version
Start test with the

→ key. End test with the ↵ key.

2.10.2 BACKEND.HW Monitor the backend hardware version

Start test with the

→ key. End test with the ↵ key.

2.10.3 FRONTEND.SW Monitor the frontend software version

Start test with the

→ key. End test with the ↵ key.