Technical data – KROHNE OPTISONIC 3400 EN User Manual
Page 99
TECHNICAL DATA
8
99
OPTISONIC 3400
www.krohne.com
11/2013 - 4002037702 - HB OPTISONIC 3400 -en-R02
HART
HART
HART
HART
®
Description
HART
®
protocol via active and passive current output
HART
®
version: V7
Universal HART
®
parameter: completely integrated
Load
≥ 250 Ω t HART
®
test point:
Note maximum load for current output!
Multidrop
Yes, current output = 4 mA
Multidrop addresses adjustable in operation menu 1...15
Device drivers
DD for FC 375/475, AMS, PDM, DTM for FDT
Pulse or frequency output
Pulse or frequency output
Pulse or frequency output
Pulse or frequency output
Output data
Volume flow, mass flow
Function
Adjustable as pulse of frequency output
Pulse rate/frequency
0.01...10000 pulses/s or Hz
Settings
For Q = 100%: 0.01... 10000 pulses per second or pulses
per unit volume.
Pulse width: adjustable as automatic, symmetric or fixed
(0.05...2000 ms)
Operating data
Basic I/Os
Modular I/Os
Ex i
Active
-
U
nom
= 24 VDC
-
f
max
in operating
menu set to:
ffff
max
max
max
max
≤ 100 Hz:
100 Hz:
100 Hz:
100 Hz:
I ≤ 20 mA
R
L, max
= 47 kΩ
open:
I ≤ 0.05 mA
closed:
U
0,nom
= 24 V at
I = 20 mA
F
max
in operating
menu set to:
100 Hz < f
100 Hz < f
100 Hz < f
100 Hz < f
max
max
max
max
≤ 10
10
10
10
kHz:
kHz:
kHz:
kHz:
I ≤ 20 mA
R
L
≤ 10 kΩ for f ≤
1 kHz
R
L
≤ 1 kΩ for f ≤
10 kHz
open:
I ≤ 0.05 mA
closed:
U
0,nom
= 22.5 V at
I = 1 mA
U
0,nom
= 21.5 V at
I = 10 mA
U
0,nom
= 19 V at
I = 20 mA