Description of hart interface, 6 process variables root menu, Measured values overview – KROHNE OPTISONIC 3400 EN User Manual
Page 130: Output, hart dynamic variables, Totaliser overview, Diagnosis overview
9
DESCRIPTION OF HART INTERFACE
130
OPTISONIC 3400
www.krohne.com
11/2013 - 4002037702 - HB OPTISONIC 3400 -en-R02
9.11.6 Process Variables Root Menu
Measured Values Overview
•
Volume Flow
Rd
•
Volume Flow Data Quality
Rd
•
Volume Flow Limit Status
Rd
•
Velocity of Sound
Rd
•
Velocity of Sound Data Quality
Rd
•
Velocity of Sound Limit Status
Rd
•
Mass Flow
Rd
•
Mass Flow Data Quality
Rd
•
Mass Flow Limit Status
Rd
•
Flow Velocity
Rd
•
Flow Velocity Data Quality
Rd
•
Flow Velocity Limit Status
Rd
•
Gain
Rd
•
Gain Data Quality
Rd
•
Gain Limit Status
Rd
•
SNR
Rd
•
SNR Data Quality
Rd
•
SNR Limit Status
Rd
•
Time Stamp
Rd
•
Ext. Field Device Status (0x08)
Rd
•
Ext. Field Device Status (0x20)
Rd
•
Ext. Field Device Status (0x10)
Rd
•
Ext. Field Device Status (0x01)
Rd
Output, HART Dynamic Variables
Primary
•
Measured Value
Rd
•
Percent Range
Rd
•
Loop Current
Rd
Secondary
•
Measured Value
Rd
•
Percent Range
Rd, Opt
•
Output Value
Rd, Opt
Tertiary
•
Measured Value
Rd
•
Percent Range
Rd, Opt
•
Output Value
Rd, Opt
Quaternary
•
Measured Value
Rd
•
Percent Range
Rd, Opt
•
Output Value
Rd, Opt
Totaliser Overview
•
Mass Totaliser 1
Rd, Opt
•
Mass Totaliser 1 Data Quality
Rd, Opt
•
Mass Totaliser 1 Limit Status
Rd, Opt
•
Volume Totaliser 1
Rd, Opt
•
Volume Totaliser 1 Data Quality
Rd, Opt
•
Volume Totaliser 1 Limit Status
Rd, Opt
•
Mass Totaliser 2
Rd, Opt
•
Mass Totaliser 2 Data Quality
Rd, Opt
•
Mass Totaliser 2 Limit Status
Rd, Opt
•
Volume Totaliser 2
Rd, Opt
•
Volume Totaliser 2 Data Quality
Rd, Opt
•
Volume Totaliser 2 Limit Status
Rd, Opt
•
Mass Totaliser 3
Rd, Opt
•
Mass Totaliser 3 Data Quality
Rd, Opt
•
Mass Totaliser 3 Limit Status
Rd, Opt
•
Volume Totaliser 3
Rd, Opt
•
Volume Totaliser 3 Data Quality
Rd, Opt
•
Volume Totaliser 3 Limit Status
Rd, Opt
•
Time Stamp
Rd
Diagnosis Overview
•
Diagnosis Flow Velocity
Rd, Opt
•
Diagnosis Flow Velocity Data Quality
Rd, Opt
•
Diagnosis Flow Velocity Limit Status
Rd, Opt
•
Diagnosis Velocity of Sound
Rd, Opt
•
Diagnosis Velocity of Sound Data Quality
Rd, Opt
•
Diagnosis Velocity of Sound Limit Status
Rd, Opt
•
Diagnosis Gain
Rd, Opt
•
Diagnosis Gain Data Quality
Rd, Opt
•
Diagnosis Gain Limit Status
Rd, Opt
•
Diagnosis SNR
Rd, Opt
•
Diagnosis SNR Data Quality
Rd, Opt
•
Diagnosis SNR Limit Status
Rd, Opt
•
Operating Hours
Rd
•
Operating Hours Data Quality
Rd
•
Operating Hours Limit Status
Rd
•
Time Stamp
Rd
Table 9-1: Designations;
Designations;
Designations;
Designations;
Opt
; Optional, depent on device implementation / configuration
Rd
; Read-only