beautypg.com

Description of hart interface, 6 process variables root menu, Measured values overview – KROHNE OPTISONIC 3400 EN User Manual

Page 130: Output, hart dynamic variables, Totaliser overview, Diagnosis overview

background image

9

DESCRIPTION OF HART INTERFACE

130

OPTISONIC 3400

www.krohne.com

11/2013 - 4002037702 - HB OPTISONIC 3400 -en-R02

9.11.6 Process Variables Root Menu

Measured Values Overview

Volume Flow

Rd

Volume Flow Data Quality

Rd

Volume Flow Limit Status

Rd

Velocity of Sound

Rd

Velocity of Sound Data Quality

Rd

Velocity of Sound Limit Status

Rd

Mass Flow

Rd

Mass Flow Data Quality

Rd

Mass Flow Limit Status

Rd

Flow Velocity

Rd

Flow Velocity Data Quality

Rd

Flow Velocity Limit Status

Rd

Gain

Rd

Gain Data Quality

Rd

Gain Limit Status

Rd

SNR

Rd

SNR Data Quality

Rd

SNR Limit Status

Rd

Time Stamp

Rd

Ext. Field Device Status (0x08)

Rd

Ext. Field Device Status (0x20)

Rd

Ext. Field Device Status (0x10)

Rd

Ext. Field Device Status (0x01)

Rd

Output, HART Dynamic Variables

Primary

Measured Value

Rd

Percent Range

Rd

Loop Current

Rd

Secondary

Measured Value

Rd

Percent Range

Rd, Opt

Output Value

Rd, Opt

Tertiary

Measured Value

Rd

Percent Range

Rd, Opt

Output Value

Rd, Opt

Quaternary

Measured Value

Rd

Percent Range

Rd, Opt

Output Value

Rd, Opt

Totaliser Overview

Mass Totaliser 1

Rd, Opt

Mass Totaliser 1 Data Quality

Rd, Opt

Mass Totaliser 1 Limit Status

Rd, Opt

Volume Totaliser 1

Rd, Opt

Volume Totaliser 1 Data Quality

Rd, Opt

Volume Totaliser 1 Limit Status

Rd, Opt

Mass Totaliser 2

Rd, Opt

Mass Totaliser 2 Data Quality

Rd, Opt

Mass Totaliser 2 Limit Status

Rd, Opt

Volume Totaliser 2

Rd, Opt

Volume Totaliser 2 Data Quality

Rd, Opt

Volume Totaliser 2 Limit Status

Rd, Opt

Mass Totaliser 3

Rd, Opt

Mass Totaliser 3 Data Quality

Rd, Opt

Mass Totaliser 3 Limit Status

Rd, Opt

Volume Totaliser 3

Rd, Opt

Volume Totaliser 3 Data Quality

Rd, Opt

Volume Totaliser 3 Limit Status

Rd, Opt

Time Stamp

Rd

Diagnosis Overview

Diagnosis Flow Velocity

Rd, Opt

Diagnosis Flow Velocity Data Quality

Rd, Opt

Diagnosis Flow Velocity Limit Status

Rd, Opt

Diagnosis Velocity of Sound

Rd, Opt

Diagnosis Velocity of Sound Data Quality

Rd, Opt

Diagnosis Velocity of Sound Limit Status

Rd, Opt

Diagnosis Gain

Rd, Opt

Diagnosis Gain Data Quality

Rd, Opt

Diagnosis Gain Limit Status

Rd, Opt

Diagnosis SNR

Rd, Opt

Diagnosis SNR Data Quality

Rd, Opt

Diagnosis SNR Limit Status

Rd, Opt

Operating Hours

Rd

Operating Hours Data Quality

Rd

Operating Hours Limit Status

Rd

Time Stamp

Rd

Table 9-1: Designations;

Designations;

Designations;

Designations;

Opt

; Optional, depent on device implementation / configuration

Rd

; Read-only