beautypg.com

Operation, 4 description of functions – KROHNE OPTISONIC 3400 EN User Manual

Page 79

background image

OPERATION

6

79

OPTISONIC 3400

www.krohne.com

11/2013 - 4002037702 - HB OPTISONIC 3400 -en-R02

6.4 Description of functions

6.4.1 Reset totaliser in the menu "Quick Setup"

6.4.2 Deleting error messages in the menu "Quick Setup"

INFORMATION!
It may be necessary to activate resetting of the totaliser in the menu "Quick Setup".

Key

Display

Description and setting

>

Quick Setup

Press and hold for 2.5 s, then release the key.

>

Language

-

2 x ↓

Reset

-

>

Reset Errors

-

All Totaliser

Select desired totaliser.

Totaliser 1

Totaliser 2

Totaliser 3

>

Reset Totaliser

No

-

↓ or ↑

Reset Totaliser

Yes

-

^

Totaliser 1,2

Totaliser has been reset.

3 x ^

Measuring mode

-

INFORMATION!
The detailed list of the possible error messages.

Key

Display

Description and setting

>

Quick Setup

Press and hold for 2.5 s, then release the key.

>

Language

-

2 x ↓

Reset

-

>

Reset Errors

-

>

Reset?

No

-

↓ or ↑

Reset?

Yes

-

^

Reset Errors

Error has been reset.

3 x ^

Measuring mode

-