OPERATION

76

OPTISONIC 3400

www.krohne.com

11/2013 - 4002037702 - HB OPTISONIC 3400 -en-R02

C5.5 Graphic Page

C5.5

Graphic Page

-

C5.5.1

Select Range

Graphic page always shows trend curve of the measurement of the 1st page

/ 1st line, see Fct. C6.3.2

Select: Manual (set range in Fct. C5.5.2) ; Automatic (automatic depiction

based on the measured values)

Reset only after parameter change or after switching off and on.

C5.5.2

Range

Set the scaling for the Y axis. Only available if "Manual" is set in C5.5.1.

±

xxx ±xxx%; range: -100…+100%

(1st value = lower limit / 2nd value = upper limit),

condition: 1st value ≤ 2nd value

C5.5.3

Time Scale

Set the time scaling for the X axis, trend curve

xxx min; range: 0…100 min

C5.6 Special Functions

C5.6

Special Functions

-

C5.6.1

Reset Errors

Reset Errors?

Select: No / Yes

C5.6.2

Save Settings

Save current settings.
Select: Break (exit function without saving) / Backup 1 (save in storage
location 1) / Backup 2 (save in storage location 2)

Query: Continue To Copy? (cannot be done afterwards)
Select: No (exit function without saving) / Yes (copy current settings to
storage backup 1 or backup 2)

C5.6.3

Load Settings

Load saved settings
Select: Break (exit function without loading) / factory settings (restore
factory settings) / backup 1 (load data from storage location 1) / backup 2
(load data from storage location 2)

Query: Continue To Copy? (cannot be done afterwards)
Select: No (exit the function without saving) / Yes (load data from the
selected storage location)

C5.6.4

Password Quick Set

Password required to change data in the quick setup menu.

0000 (= to quick setup menu without password)

xxxx (password required); range 4 digits: 0001…9999

C5.6.5

Password Setup

Password required to change data in the setup menu

0000 (= to quick setup menu without password)

xxxx (password required); range 4 digits: 0001…9999

C5.6.6

Date and Time

Set real time

C5.6.7

Quick Access

Set Quick Access function;

Select: Off (deactivated) / Reset Totaliser 1, 2, 3 or All Totalisers

C5.6.8

GDC IR Interface

After this function has been activated an optical GDC adapter can be
connected to the LC display. If approximately 60 seconds pass without a
connection being established or after the adapter is removed, then the
function is exited and the optical keys are active once again.

Break (exit function without connection)

Activate (the IR interface adapter and interrupt the optical keys)

If approximately 60 seconds pass without a connection being established,
then the function is exited and the optical keys are active once again.