Operation – KROHNE OPTISONIC 3400 EN User Manual
Page 76
6
OPERATION
76
OPTISONIC 3400
www.krohne.com
11/2013 - 4002037702 - HB OPTISONIC 3400 -en-R02
C5.5 Graphic Page
C5.5
Graphic Page
-
C5.5.1
Select Range
Graphic page always shows trend curve of the measurement of the 1st page
/ 1st line, see Fct. C6.3.2
Select: Manual (set range in Fct. C5.5.2) ; Automatic (automatic depiction
based on the measured values)
Reset only after parameter change or after switching off and on.
C5.5.2
Range
Set the scaling for the Y axis. Only available if "Manual" is set in C5.5.1.
±
xxx ±xxx%; range: -100…+100%
(1st value = lower limit / 2nd value = upper limit),
condition: 1st value ≤ 2nd value
C5.5.3
Time Scale
Set the time scaling for the X axis, trend curve
xxx min; range: 0…100 min
C5.6 Special Functions
C5.6
Special Functions
-
C5.6.1
Reset Errors
Reset Errors?
Select: No / Yes
C5.6.2
Save Settings
Save current settings.
Select: Break (exit function without saving) / Backup 1 (save in storage
location 1) / Backup 2 (save in storage location 2)
Query: Continue To Copy? (cannot be done afterwards)
Select: No (exit function without saving) / Yes (copy current settings to
storage backup 1 or backup 2)
C5.6.3
Load Settings
Load saved settings
Select: Break (exit function without loading) / factory settings (restore
factory settings) / backup 1 (load data from storage location 1) / backup 2
(load data from storage location 2)
Query: Continue To Copy? (cannot be done afterwards)
Select: No (exit the function without saving) / Yes (load data from the
selected storage location)
C5.6.4
Password Quick Set
Password required to change data in the quick setup menu.
0000 (= to quick setup menu without password)
xxxx (password required); range 4 digits: 0001…9999
C5.6.5
Password Setup
Password required to change data in the setup menu
0000 (= to quick setup menu without password)
xxxx (password required); range 4 digits: 0001…9999
C5.6.6
Date and Time
Set real time
C5.6.7
Quick Access
Set Quick Access function;
Select: Off (deactivated) / Reset Totaliser 1, 2, 3 or All Totalisers
C5.6.8
GDC IR Interface
After this function has been activated an optical GDC adapter can be
connected to the LC display. If approximately 60 seconds pass without a
connection being established or after the adapter is removed, then the
function is exited and the optical keys are active once again.
Break (exit function without connection)
Activate (the IR interface adapter and interrupt the optical keys)
If approximately 60 seconds pass without a connection being established,
then the function is exited and the optical keys are active once again.