DESCRIPTION OF HART INTERFACE

138

OPTISONIC 3400

www.krohne.com

11/2013 - 4002037702 - HB OPTISONIC 3400 -en-R02

9.11.10 Offline Root Menu

Identification

Identification

Identification

Identification

Identification

Tag / Long Tag / Descriptor / Message / Date

Device

Manufacturer

Rd

/ Device Type

Rd

/ HART Device ID

Rd

/ Final Assembly Number / Device

Serial No.

Rd

/ C number

Rd

/

Rd

/ Electronic Serial No.

Rd

Detailed Setup

Detailed Setup

Detailed Setup

Detailed Setup

Mapping of Variables

PV is / SV is / TV is / QV is

Process Input

Meter Size

Meter Size

Calibration

/ GK

Filter

Minimum Limit / Maximum Limit / Flow Direction /

Threshold Low Flow Cutoff / Hysteresis Low Flow Cutoff

Plausibility

Error Limit / Counter Decrease / Counter Limit

Information

/ / / V No. Sensor

Rd

/ Serial Number

Sensor

Rd

/ V no. Converter

Rd

Linearization

Linearization / Dynamic Viscosity

Opt

Pipe Temperature

Pipe Temperature

Density

Density

Diagnosis

2 / Diagnostics 2

Status Mapping

Electronics;

Electronics;

Electronics;

Electronics; IO Connection / Power Failure

Process:

Process:

Process:

Process: Empty Pipe / Signal Lost / Signal Unreliable

Configuration:

Configuration:

Configuration:

Configuration: Totaliser

HART

Sensor s/n /

Volume Flow / Velocity of Sound / Mass Flow / Flow Speed / Gain / SNR / Diagnosis VoS /

Diagnosis SNR / Operating Hours / Totaliser,
Unit / Format / Upper Sensor Limit

Rd

/ Lower Sensor Limit

Rd

/ Minimum Span

Rd

/ Family

Rd

/ Class

Rd

/ Update Time

Rd

I/O

Hardware

Terminals A / Terminals B / Terminals C / Terminals D

Current Output
A/B/C

Opt

Range 0% / Range 100% / Extended Range Min / Extended Range Max / Error Current /
Error Condition / Measurement / Range Min / Range Max / Polarity

Cust

/ Limitation Min /

Limitation Max / LFC Threshold / LFC Hysteresis / Time Constant / Special Function /
Threshold Range Change

Opt

/ Hysteresis Range Change

Opt

Frequency Output
A/B/D

Opt

Pulse Shape

Opt

/ Pulse Width

Opt

/ 100% Pulse Rate

Opt

/ Measurement /Range Min /

Range Max / Polarity / Limitation Min /Limitation Max / LFC Threshold / LFC Hysteresis /
Time Constant /Invert Signal / Special Function

Opt

/ Phase Shift

Opt

Pulse Output
A/B/D

Opt

Pulse Shape

Opt

/ Pulse Width

Opt

/ Max. Pulse Rate

Opt

/ Measurement / Pulse Value Unit

Rd

/ Value Per Pulse / Pulse value Unit / Polarity / LFC Threshold / LFC Hysteresis / Time

Constant / Invert Signal / Special Function

Opt

/ Phase Shift

Opt

Status Output
A/B/C/D

Opt

Mode / Output A

Opt

/ Output B

Opt

/ Output C

Opt

/ Output D

Opt

/ Invert Signal

Limit Switch
A/B/C/D

Opt

Measurement / Threshold / Hysteresis / Polarity / Time Constant / Invert Signal