ELECTRICAL CONNECTIONS

4

49

OPTISONIC 3400

www.krohne.com

11/2013 - 4002037702 - HB OPTISONIC 3400 -en-R02

Control input active, modular I/Os

• U

int

= 24 VDC

• External contact open:

U

0, nom

= 22 V

External contact closed:
I

nom

= 4 mA

• Switching point for identifying "contact open or closed":

Contact open (off): U

0

≤ 10 V with I

nom

= 1.9 mA

Contact closed (on): U

0

≥ 12 V with I

nom

= 1.9 mA

• X designates the connection terminals A or B, depending on the version of the signal

converter.

Control input passive, modular I/Os

• 3 V ≤ U

ext

≤ 32 VDC

• I

max

= 9.5 mA at U

ext

≤ 24 V

I

max

= 9.5 mA at U

ext

≤ 32 V

• Switching point for identifying "contact open or closed":

Contact open (off): U

0

≤ 2.5 V with I

nom

= 1.9 mA

Contact closed (on): U

0

≥ 3 V with I

nom

= 1.9 mA

• X designates the connection terminals A or B, depending on the version of the signal

converter.

CAUTION!
Observe connection polarity.

Figure 4-20: Control input active C

a

1 Signal

Figure 4-21: Control input passive C

p

1 Signal