TECHNICAL DATA

8

103

OPTISONIC 3400

www.krohne.com

11/2013 - 4002037702 - HB OPTISONIC 3400 -en-R02

PROFIBUS PA

PROFIBUS PA

PROFIBUS PA

PROFIBUS PA

Description

Galvanically isolated acc. to IEC 61158

Profile version: 3.02

Current consumption: 10.5 mA

Permissible bus voltage: 9...32 V; in Ex application 9...24 V

Bus interface with integrated reverse polarity protection

Typical error current FDE (Fault Disconnection Electronic): 4.3

mA

Bus address adjustable via local display on the measuring

device

Function blocks

6 x analogue input, 3 x totaliser

Output data

Volume flow, mass flow, velocity of sound, flow speed, gain,

SNR, electronic temperature, power supply

(Further meas. values and diagnostic data is available via acyclic

access)

FOUNDATION Fieldbus

FOUNDATION Fieldbus

FOUNDATION Fieldbus

FOUNDATION Fieldbus

Description

Galvanically isolated acc. to IEC 61158

Current consumption: 10.5 mA

Permissible bus voltage: 9...32 V; in Ex application 9...24 V

Bus interface with integrated reverse polarity protection

Link Master function (LM) supported

Tested with Interoperable Test Kit (ITK) version 6.0

Function blocks

1 x analogue input, 2 x integrator, 1 x PID

Output data

Volume flow, mass flow, flow speed, electronic temperature,

velocity of sound, gain, SNR

Diagnostic data

MODBUS

MODBUS

MODBUS

MODBUS

Description

Modbus RTU, Master / Slave, RS485

Address range

1…247

Supported function codes

01, 02, 03, 04, 05, 08, 16, 43

Supported Baudrate

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Baud