Operation – KROHNE OPTISONIC 3400 EN User Manual
Page 67
OPERATION
6
67
OPTISONIC 3400
www.krohne.com
11/2013 - 4002037702 - HB OPTISONIC 3400 -en-R02
C1.5.1 Volume flow
Simulation of volume flow
C1.5.2 Velocity of sound
Simulation of velocity of sound
C1.6
Information
Information
C1.6.1 Sensor CPU
Displays the ID of the CPU on the FrontEnd
C1.6.2 Sensor DSP
Displays the ID of the DSP on the FrontEnd
C1.6.3 Sensor driver
Displays the ID of the Sensor Driver on the FrontEnd
C1.6.4 Calibration date
Displays the date of calibration of the sensor
C1.6.5 Serial no. Sensor
Displays the serial number of the measuring sensor
C1.6.6 V no. Sensor
Displays the Order number of the measuring sensor
C1.7
Linearization
Linearization
C1.7.1 Linearization
Compensation for errors made at different Reynolds numbers
C1.7.2 Dynamic viscosity
Sets the value of the dynamic viscosity for Reynolds calculation
C1.8
Pipe temperature
Temperature compensation
C1.9
Density
Sets the density of the fluid
C1.10
Diagnosis
C1.10.1 Diagnosis 1
Sets the parameter to be assigned to cyclic value; none, flow speed (1-2-3),
velocity of sound (1-2-3)
C1.10.2 Diagnosis 2
Sets the parameter to be assigned to cyclic value ; none, gain (1-2-3), SNR
(1-2-3)
C1.10.3 Proc: Empty pipe
Change NE107 status signal for status group "Proc: Empty pipe"
C1.10.4 Proc: Signal Lost
Change NE107 status signal for status group "Proc: Signal Lost"
C1.10.5 Proc: Signal
Unreliable
Change NE107 status signal for status group "Proc: Signal Unreliable"
C1.10.6 Config: Totaliser
Change NE107 status signal for status group "Config: Totaliser"
C1.10.7 Electr: IO
Connection
Change NE107 status signal for status group "Electr: IO Connection"
C1.10.8 Electr: Power
Failure
Change NE107 status signal for status group "Electr: Power Failure"
No.
Function
Settings / descriptions
C2 I/O
C2_
I/O
C2.1
Hardware
Configuration of connection terminals. Selection depends on signal
converter version.
C2.1.1 Terminal A
Sets the output associated with terminal A
Select: Off (switched off) / current output / frequency output / pulse output /
status output / limit switch / control input
C2.1.2 Terminal B
Sets the output associated with terminal B
Select: Off (switched off) / current output / frequency output / pulse output /
status output / limit switch / control input
C2.1.3 Terminal C
Sets the output associated with terminal C
Select: Off (switched off) / current output / status output / limit switch
C2.1.4 Terminal D
Sets the output associated with terminal D
Select: Off (switched off) / frequency output / pulse output / status output /
limit switch
No.
Function
Settings / descriptions