Operation, 3 function tables, 1 menu a, quick setup – KROHNE OPTISONIC 3400 EN User Manual
Page 63
OPERATION
6
63
OPTISONIC 3400
www.krohne.com
11/2013 - 4002037702 - HB OPTISONIC 3400 -en-R02
6.3 Function tables
6.3.1 Menu A, Quick Setup
INFORMATION!
•
The following tables describe the functions of the standard device with HART
®
connection.
The functions for Modbus, Foundation Fieldbus and Profibus are described in detail in the
corresponding supplementary instructions.
•
Depending on the device version, not all functions are available.
No.
Function
Setting / Description
A1 Language
A1
Language
Language selection depends on the device version.
A2 Tag
A2
Tag
Measuring point identifier (Tag no.) (also for HART
®
operation) appears in
the LCD header (max. 8 digits).
A3 Reset
A3
Reset
A3.1
Reset Errors
Reset Errors? Select: no/yes
A3.2
Totaliser 1
Reset Totaliser? Select: No / Yes
A3.3
Totaliser 2
Reset Totaliser? Select: No / Yes
A3.4
Totaliser 3
Reset Totaliser? Select: No / Yes
A4 Analogue Outputs (only for HART
®
)
A4
Analogue Outputs
Applicable to all current outputs (terminals A, B and C), frequency outputs
(terminals A, B and D), limit switch (terminals A, B, C, and / or D) and the 1st
display page / line 1.
A4.1
Measurement
1) Select measurement: Volume Flow / Velocity of Sound/ / Mass Flow /
Flow Speed / Gain / SNR / Diagnostics 1 / Diagnostics 2 /
2) Use for all outputs? (also use this setting for Fct. A4.2...A4.5!)
Setting: no (applies only to the main current output ) / yes (applies to all
analogue outputs)
A4.2
Unit
Selection of the unit from a list, depending on the measurement.
A4.3
Range
1) Setting for main current output (range: 0...100%)
Setting: 0…x.xx (format and unit, depending on measurement, see A4.1 and
A4.2 above)
2) Use for all outputs? Make setting, see Fct. A4.1 above!
A4.4
Low Flow Cutoff
1) Setting for main current output (sets output value to "0")
Setting: x.xxx ± x.xxx% (Range: 0.0…20%)
(1st value = switching point / 2nd value = hysteresis),
condition: 2nd value ≤ 1st value
2) Use for all outputs? Make setting, see Fct. A4.1 above!
A4.5
Time Constant
1) Setting for main current output (applicable to all flow measurements)
Setting: xxx.x s (range: 000.1…100 s)
2) Use for all outputs? Make setting, see Fct. A4.1 above!