beautypg.com

Ir fail timing, Gb fail timing – GW Instek GPT-9900 series User Manual User Manual

Page 72

background image

GPT-9000/9000A Series User Manual

72

IR FAIL Timing

START
TEST
FAIL

Discharge time

Output V

time

Initial time
(100ms)

RAMP

TEST TIME

GB FAIL Timing

Output I

time

START
TEST
FAIL

0.5s

Initial time
(100ms)

Total Test Time