beautypg.com

Manu:edit:mode, Manu:acw:voltage – GW Instek GPT-9900 series User Manual User Manual

Page 131

background image

REMOTE CONTROL

131

is over 30mA (GPT-98XX) or over 80mA (GPT-
99XX/99XXA). This applies to the ACW function
only.

Syntax
Query Syntax

MANU:RTIMe
MANU:RTIMe?

Parameter/
Return parameter

0.1~999.9 seconds

Example

MANU:RTIM 0.5
Sets the ramp time to half a second.

MANU:EDIT:MODE

Set

Query

Description

Sets or returns the mode (ACW, DCW, IR, GB) of
the selected manual test.

Syntax
Query Syntax

MANU:EDIT:MODE {ACW|DCW|IR|GB}
MANU:EDIT:MODE?

Parameter/
Return parameter

ACW

AC Withstand mode

DCW

DC Withstand mode

IR

Insulation Resistance mode

GB

Ground Bond mode

Example

MANU:EDIT:MODE ACW
Sets the mode to ACW.

MANU:ACW:VOLTage

Set

Query

Description

Sets or returns the ACW voltage in kV. The test
must first be in ACW mode before this command
can be used.

Syntax
Query Syntax

MANU:ACW:VOLTage
MANU:ACW:VOLTage?

Parameter/
Return parameter

0.100 ~ 5.000 (kV)

Example

MANU:ACW:VOLT 1
Sets the ACW voltage to 1 kV.