168

Current Best Resolution

GPT-98XX:
1uA
0.001mA(0.001mA~0.999mA)
0.01mA(01.00mA~09.99mA)
0.1mA(010.0mA)

GPT-99XX/99XXA:
1uA
0.001mA(0.001mA~1.100mA)
0.01mA(01.11mA~11.00mA)
0.1mA(011.0mA~020.0mA)

Current Measurement
Accuracy

GPT-98XX:
± (1.5% of rdg + 30 counts) when HI SET <1.00mA
(1.5% of rdg + 3 counts) when HI SET ≥1.00mA

GPT-99XX/99XXA:
± (1.5% of rdg + 30 counts) when HI SET <1.11mA
(1.5% of rdg + 3 counts) when HI SET ≥1.11mA

Window Comparator Method Yes
ARC DETECT

Yes

Rise-time Control Function

Yes

RAMP (Ramp Time)

0.1~999.9S

TIMER (Test Time)

OFF*, 0.5S~999.9S

GND

ON/OFF

* The timer can only be turned off under special MANU mode (MANU=***-000)


Insulation Resistance Test
Output Voltage

50V~1000V *GPT-99XX/99XXA also includes a
125V test point.

Output Voltage Resolution

50V

Output Voltage Accuracy

(1% of setting+5V) with no load

Resistance Measurement
Range

1M

~ 9500M

(GPT-98XX)

1M

~ 50G

(GPT-99XX/99XXA)

Test Voltage

Measurement Range Accuracy

(GPT-98XX) 50V≤V≤450V

1~50MΩ

±(5% of reading +1 count)

51~2000MΩ

±(10% of reading +1 count)

500V≤V≤1000V 1~500MΩ

±(5% of reading +1 count)

501~9500MΩ

±(10% of reading +1 count)

(GPT-99XX/
99XXA)

50V≤V≤450V

0.001~0.050GΩ

±(5% of reading +1 count)

0.051~2.000GΩ

±(10% of reading +1 count)

500V≤V≤1000V 0.001~0.500GΩ

±(5% of reading +1 count)

0.501~9.999GΩ

±(10% of reading +1 count)

10.00~50.00GΩ

±(15% of reading +1 count)