Syntax
Query Syntax

MANU:GB:TTIMe
MANU:GB:TTIMe?

Parameter/
Return parameter

0.5 ~ 999.9 seconds

Example

MANU:GB:TTIM 1
Sets the GB test time to 1 second.

MANU:GB:FREQuency

Set

Query

Description

Sets or returns the GB test frequency in Hz. The
test must first be in GB mode before this command
can be used.

Syntax
Query Syntax

MANU:GB:FREQuency {50|60}
MANU:GB:FREQuency?

Parameter/
Return parameter

50

50 Hz

60

60 Hz

Example

MANU:GB:FREQ 50
Sets the GB test frequency to 50Hz.

MANU:GB:REF

Set

Query

Description

Sets or returns the GB reference value in mΩ. The
test must first be in GB mode before this command
can be used.

The GB reference value must be less than the HI
SET value.

Syntax
Query Syntax

MANU:GB:REF
MANU:GB:REF?

Parameter/
Return parameter

0.000 ~ 649.9

Example

MANU:GB:REF 100
Sets the GB reference to 100 mΩ.