beautypg.com

Error messages, System self test – GW Instek GPT-9900 series User Manual User Manual

Page 163

background image

APPENDIX

163

220

100

12

0

23

0

220

100

12

0

23

0

Rating

The fuse for the GPT-98XX and the GPT-
99XX/99XXA have different ratings:

GPT-98XX:

100V/120V

T5A 250V

220V/230V

T2.5A 250V

GPT-99XX/99XXA:

100V/120V

T10A 250V

220V/230V

T6.3A 250V

Error Messages

System Self Test

The following error messages or messages may appear on the GPT
screen during the Start-Up initialization. If any of these error messages
appear on the GPT-9000/9000A, please see an authorized GW Instek
distributor.

Error Messages

Description

0x11

EEPROM1 Error

0x12

EEPROM1 Error

0x21

W-V Offset Error (W-V: ACW/DCW voltage)

0x22

W-I Offset Error (W-I: ACW/DCW current)

0x23

IR-I Offset Error

0x24

GB-I Offset Error