background image

Part No. 4801-5396 Rev. 5-08

Unitized System - Square Reservoir

Page 9 of 63

Front View

Splice

12" Between

Brackets

(Splice in Center)

Splice

L-Bracket












































Flat Bottom Reservoir Support Brackets – End Pump Only

1.

Determine the height at which the bottom of the MegaCool system should be mounted above the ground. Make a
mark on each end post to represent the height.

IMPORTANT: The height of the bottom of the System should be a minimum of 9-1/2 inches above the ground in order

to elevate the pump above ground. Failure to do so may void the motor warranty.

2.

Stretch a chalk line between marks of end posts.

3.

Align bottom edge of metal support bracket with chalk line distances shown above. Use 1/4" x 1-1/2" Lag screws
for wood framing, or, #14 x 1"Hex Head TEK screws for metal framing.

4.

Assemble L-Brackets to support brackets as shown above with 1/4"-20 hex bolts and 1/4" -20 nuts.

Left

Right

Center

108 1/4"

Typ

12"

Typ

4"

Typ

58 1/4"