Hired-Hand Manual Light Dimmer User Manual
Manual light dimmer, Installation, Operation
MANUAL LIGHT DIMMER
GND
Hot
In
Hot
Out
Hot
In
Hot
Out
Warnings!
High Voltage present inside the controller. If you need to reach inside the controller
disconnect power first.
This product shoud be used to adjust the light intensity on incandescent light bulbs
only. Hired Hand is not liable for any problems that may arise from use with other
lighting systems.
Tools Required
Screwdriver
Cordless Drill
Wire Strippers
Installation
1. Hang the Manual Light Dimmer using the four
screws provided.
2. Make sure all power supplies are disconnected
before breaking any wires.
3. Open the Manual Light Dimmer, and find all
connections. See fig. 1
4. Connect all wires using the wiring diagram in
fig. 1 below.
5. Re-connect power.
6. Installation complete.
J2
J3
J9
J8
J7
J4
J6
J5
J10
J11
J12
C2
TR1
R1
R3
R6
R4
R2
R5
R8
R7
5k
C1
TR3
MBS4991
TR4
MBS4991
TR2
GND
Hot
In
Hot
Out
Hot
In
Hot
Out
Branch 1
Branch 1
Branch 2
Branch 2
Center
ON
Control
Control
Copyright (c) 1998, '99
Copyright (c) 1998, '99
Hired-Hand, Inc
Hired-Hand, Inc
Farmhand Manual Light Dimmer
Farmhand Manual Light Dimmer
Pcb 150 rev 'A'
Pcb 150 rev 'A'
HIRED-HAND INC.
1733 Co Rd Bremen, AL 35033
Phone 256-287-1000
Fax 256-287-2000
•
•
•
Manual Part No. 4801-5040 rev 11-05
Branch
1
Branch
1
Branch
2
Branch
2
Hot (120vac)
Hot (120vac)
Neutral
Neutral
Lights
Earth Ground
Fig. 1
Operation
1. To place full power on incandescent light blubs,
place switch to
position. See fig. 2
2. To turn incandescent light blubs off,
place switch to
positon.
See fig. 2
3. To adjust light intensity, place switch to
position, adjust the lights using the
knob in the center. See fig. 2
On
Off
Variable
Fig. 2
4501-5071
Manual Light
Dimmer
Variable
Variable
On
(prendido)
(prendido)
Electrical shock may occur if the enclosure is opened
with power connected to the unit. Wiring and connections must comply
with all national and local electrical codes. Installation by qualified
electrician required!
On
Circuit 1
Circuit 2
Off
Off
Off
Off
3
2
1
4
5
6
7
8
9
10
Warning!
(circuito 1)
(variable)
(variable)
(circuito 2)
Knob
(Variable Adjust)
Lights
O
N
O
F
F
20
O
N
O
F
F
20
20 Amp
20 Amp
Breaker
Box
Ratings and Specifications
Room Temp: 122 F / 50°C Maximum
Input :
120 VAC 50/60 Hz
Output:
4800 Watts, 40 Amps Maximum
Per Circuit: 2400 Watts, 20 Amps Maximum
*Circuits Should Be Fused @ 20 Amps Max.
°
HIRED-HAND
Circuits Should Be Protected With A
Breaker Rated At 20 Amps Maximum.
IMPORTANT